Description
Metso IOP371 I/O Bus Extender Module, Industrial Automation Spare Part

IOP371
Product Overview
The Metso IOP371 is an I/O bus extender module for Metso DNA distributed control system, used to extend the I/O bus distance and expand remote I/O rack connectivity. It transmits control and diagnostic signals between the main controller rack and remote I/O stations over longer cable runs. This original imported spare is widely stocked for maintenance and emergency replacement of pulp & paper, power and chemical plants running Metso DCS.
Key Technical Specifications
- Part Number: IOP371
- Brand: Metso (Valmet)
- Module Type: I/O Bus Extender
- Compatible Platform: Metso DNA DCS
- Bus Interface: Metso proprietary I/O bus
- Power Supply: 24 VDC
- Operating Temperature: 0 °C ~ +60 °C
- Storage Temperature: -40 °C ~ +85 °C
- Relative Humidity: 5% ~ 95 %, non-condensing
- Mounting: Plug-in inside Metso I/O rack
- Hot Swap: Hot-swappable
- Status Indication: LED indicators for power, run, bus fault and link status
- Isolation: Galvanic isolation between local and extended bus segments
- Weight: Approx. 0.35 kg
Main Features
- Extends Metso DNA I/O bus for remote I/O rack installation
- Supports bus segment isolation to limit fault propagation
- Comprehensive bus diagnostics for cable break, short circuit and communication failure
- Hot-swap design, replace without shutting down the control segment
- Robust EMC protection for noisy factory cabinet environments
- Works with redundant I/O bus architecture for high availability
- Simple configuration via Metso DNA engineering tool
- Compact plug-in form factor matching standard Metso rack layout
- Enables flexible layout of distributed I/O away from main control room
- Critical legacy spare for brownfield Metso DNA control islands
Product Application Information
IOP371 acts as a repeater / extender for Metso DNA I/O bus. It regenerates bus signals and allows remote I/O racks to be installed further from the main controller rack. It forwards analog/digital process values, module diagnostic alarms and control commands between the CPU side and field I/O modules. If this extender fails, the downstream remote I/O rack will lose communication, causing loss of measurement and control for that segment. Plants hold IOP371 as spare to restore remote I/O communication quickly.
Application Scenarios
- Pulp and paper mill digester, paper machine and coating line DCS
- Power plant boiler and auxiliary process remote I/O extension
- Chemical plant distributed control skids with long cable routes
- Waste-to-energy combustion and flue gas treatment control
- Water & wastewater large pumping station remote monitoring
- Sawmill and wood processing automation control system
- Bioenergy plant boiler and fuel feeding control
- Refinery auxiliary package remote I/O expansion
- Fertilizer plant auxiliary control segment extension
- Brownfield Metso DNA DCS maintenance and spare backup
Matching / Supporting Components
- Metso DNA Controller
- Metso I/O rack and backplane
- Metso I/O modules (AI, AO, DI, DO)
- 24 VDC redundant power supply
- Shielded Metso I/O bus cable and terminal connectors
- Metso DNA engineering software
- IOP terminal base / backplane adapter
- Bus terminators for proper signal termination
- Rack cooling fan assembly
Related 12 Model References
- IOP351
- IOP348
- IOP331
- IOP320
- IOP310
- IOP304
- IOP372
- IOP373
- IOP380
- IOP391
- ACN380
- DNU380