Artesyn (Astec) LPQ252-CEF 250W Quad Output Enclosed Switching Power Supply, Industrial Automation Spare Part

  1. LPQ252-C (cover, convection without fan)
  2. LPQ252-CF (top fan variant)
  3. LPQ253-C
  4. LPQ172 series smaller power version
  5. LCM250 series replacement power supply
  6. ASTEC 73-554-002
  7. Artesyn LPT series multi-output PSU
  8. 24V cooling fan for LPQ series
  9. Input fuse kit
  10. Output terminal block
  11. Shielded AC input cable
  12. Remote sense harness
  13. 23-pin power connector
  14. Replacement electrolytic capacitor kit
  15. LQ250 newer alternative series
Category: SKU: Artesyn Brand:

Description

Artesyn (Astec) LPQ252-CEF 250W Quad Output Enclosed Switching Power Supply, Industrial Automation Spare Part

 

Product Core Overview

The LPQ252-CEF belongs to the LPQ250 series, a 250W enclosed four-output AC/DC switching power supply manufactured by Artesyn (formerly Astec, Advanced Energy). The suffix CEF means end-fan cooled version with metal cover. It adopts universal wide-range AC input and active PFC, integrates built-in EMI filter, power good signal, remote inhibit and overvoltage/overcurrent/overtemperature protection.It provides fixed +5V, +12V, -12V plus one floating adjustable 5–25V channel, widely used for industrial control racks, CNC systems, embedded equipment, test instruments and medical equipment that require multiple DC rails simultaneously.This model is officially end-of-life (EOL, last order Dec 2020). It is supplied as original surplus or fully tested refurbished spare for legacy equipment maintenance.

LPQ252-CEF

Main Technical Specifications

 

Item Specification
Brand Artesyn / Astec (Advanced Energy)
Model LPQ252-CEF
Series LPQ250
Product Type Enclosed Quad-output AC/DC Switching Power Supply
Rated Power 250W
Input 85–264 VAC (47–440 Hz) / 120–300 VDC
Output 1 +5V / 35A
Output 2 +12V / 10A
Output 3 -12V / 6A
Output 4 Floating adjustable 5~25V / 6A
Cooling End-mounted fan cooling (CEF variant)
Key Functions Active PFC, EMI filter, remote sense, remote inhibit, current share, power good signal
Protection OVP, OLP, OTP, short-circuit protection
Dimension 262 × 127 × 50.8 mm
Operating Temperature 0 ℃ ~ +50 ℃ (full load, fan cooling)
Ambient Humidity 5%–90% RH, non-condensing
Protection Rating IP20 (enclosed chassis)
Certification CE, RoHS, UL
Application Industrial control rack, CNC machine, embedded system, test bench, old medical equipment

 

Quality Control Procedure

  1. Visual Incoming Inspection: Check metal housing, fan, terminal/pin connector, label, serial number and PCB condition, confirm no burn mark or bulged capacitor.
  2. ESD Controlled Handling: All inspection and testing performed on grounded anti-static workstation with ESD wrist strap.
  3. Power-on Burn-in Test: Connect to AC source, run continuous energisation for 4 hours; monitor fan running, temperature and status signal.
  4. Output Voltage Test: Measure all four output rails under light load and full load, verify adjustable channel tuning range.
  5. Protection Function Test: Verify overvoltage, overload and short-circuit lock-off response.
  6. Signal Test: Check power good, remote inhibit and remote sense function.
  7. Ripple & Noise Test: Check output ripple within datasheet limit.
  8. Data Archiving: Record serial number and full test report, attach inspection sticker, vacuum anti-static packaging.
  9. Pre-shipment Audit: Double-check variant CEF (end fan) vs CF / C versions before dispatch.

 

Recommended Related Models & Order Codes (15pcs)

  1. LPQ252-C (cover, convection without fan)
  2. LPQ252-CF (top fan variant)
  3. LPQ253-C
  4. LPQ172 series smaller power version
  5. LCM250 series replacement power supply
  6. ASTEC 73-554-002
  7. Artesyn LPT series multi-output PSU
  8. 24V cooling fan for LPQ series
  9. Input fuse kit
  10. Output terminal block
  11. Shielded AC input cable
  12. Remote sense harness
  13. 23-pin power connector
  14. Replacement electrolytic capacitor kit
  15. LQ250 newer alternative series

 

Frequently Asked Questions

Q1: Can LPQ252-CEF replace LPQ252-CF or LPQ252-C directly?A: Voltage/current specs are identical; only cooling structure differs. CEF is end-fan, CF is top-fan, C is convection. Confirm cabinet airflow and connector pinout before swap.

Q2: Is this power supply discontinued?A: Yes, LPQ252-CEF is EOL since Dec 2020, no new production. Only surplus stock and tested refurbished available.

Q3: Does this support hot swap?A: It is chassis-mounted AC power supply. No hot swap allowed. Cut off mains input fully before removal.

Q4: No output or intermittent drop after installation, what should I check?A: Check AC input voltage & fuse, fan blockage, remote inhibit pin status, remote sense wiring, load short circuit, aging capacitors and power good signal.

Q5: Warranty terms?A: Original surplus new: 12-month warranty. Refurbished tested stock: 6-month warranty. Damage caused by wrong input voltage, output short circuit, fan failure, overloading or capacitor aging is excluded.

Q6: Commissioning software?A: No configuration software. Adjust the 4th output voltage via onboard trim potentiometer; use multimeter to verify all rail voltages.

 

Installation & Configuration Guide

Pre-installation Preparation

  • Confirm cabinet environment: good airflow, dust control, keep away from high heat components.
  • Prepare ESD protection, insulated screwdriver, multimeter, load bank and wiring drawing.
  • Perform LOTO and lock main AC power.

Installation Steps

  1. Disconnect AC mains and confirm zero voltage.
  2. Remove the old PSU, disconnect AC input and all DC output harness.
  3. Unpack new spare under ESD protection; avoid touching PCB and electrolytic capacitors.
  4. Fix the unit on chassis mounting holes.
  5. Wire AC input, all DC output channels, remote sense and remote inhibit strictly per pin definition.
  6. Confirm protective earth connection.

Configuration & Commissioning

  1. Re-energize AC input, confirm fan spins smoothly.
  2. Measure +5V, +12V, -12V; adjust potentiometer to set the 4th floating output to required voltage.
  3. Apply rated load, recheck voltage stability and ripple.
  4. Test power good signal and remote inhibit function.
  5. Clear external system alarms after stable operation.
  6. Connect to original equipment, run machine test and save commissioning log.

Maintenance Notes

  • Fan is a consumable; dust accumulation will cause over-temperature shutdown.
  • Electrolytic capacitors degrade with age, the most common failure point for these old multi-output power supplies.
  • Do not exceed rated current on any channel; overload triggers protection latch-off.
  • Store spare PSU in dry anti-static packaging.