Description
Full Model / Variant Naming
- RLX2-IHNF — Base model designation for the 802.11abgn Fast Industrial Hotspot family.
- RLX2-IHNF-A — FCC-certified model (North America), ships with a 2 dBi stub antenna.
- RLX2-IHNF-E — ETSI-certified model (Europe); RED 3.3 compliant.
- RLX2-IHNF-Z / -BR / -WC / -W-A / -W-E — Regional and weatherproof (IP66/IP67) variants for specific regulatory regions and harsh/outdoor deployments (Brazil, China, EU weatherproof, etc.).
The device is a rugged, industrial-grade Wi-Fi radio/access point rated for Wi-Fi 4 (802.11a/b/g/n) dual-band operation, engineered for plant-floor automation, SCADA, process control, and mobile-worker Wi-Fi infrastructure.

RLX2-IHNF
Core Technical Specifications
| Parameter | Specification |
|---|---|
| Wireless standard | 802.11n, 802.11a, 802.11g, 802.11h (DFS), 802.11i (Security), 802.11e (QoS), 802.11Q (VLAN), 802.11af (PoE), IGMP v2 |
| Frequency bands | 2.4 GHz (2.412–2.462 GHz FCC / 2.412–2.472 GHz ETSI) and 5 GHz (5.150–5.850 GHz, incl. DFS channels) |
| Channels | 1–11 (FCC 2.4 GHz) / 1–13 (ETSI); 36–165 across UNII-1/2/2e/3 (DFS where applicable) |
| Max data rate | Up to 300 Mbps (802.11n, MCS7, 40 MHz channel bonding) |
| Antenna | 2× antenna ports (MIMO 2×2); RP-SMA connectors; 2 dBi stub antenna included |
| Ethernet | 10/100 Mbps (or 10/100/1000 on some variants) RJ45, Auto-MDIX |
| Transmit power | 22 dBm @ MCS0/MCS8 and @ 6 Mbps; 17 dBm @ MCS7/MCS15 and @ 54 Mbps (region-dependent) |
| Operating modes | Access Point, Repeater, Client (Bridge) |
| Power input | 10–24 VDC or PoE (802.3af) |
| Power consumption | < 8 W |
| Operating temperature | −40 °C to +75 °C |
| Enclosure | Rugged aluminum, DIN-rail mount; IP66/IP67 on weatherproof variants |
| Certifications | FCC, IC, CE, cULus/UL, RoHS; ATEX/IECEx on specific versions |
Key Features and Benefits
High-performance wireless connectivity
- 802.11n MIMO & channel bonding support demanding applications such as Ethernet I/O and high-resolution video.
- Ultra-fast roaming (under 10 ms), with the datasheet citing sub-50 ms AP-to-AP switching, maintains seamless high-speed links for moving equipment (cranes, AGVs, carriers, conveyors).
- Dual-band 2.4/5 GHz with DFS lets you select clean channels and avoid interference in electromagnetic-heavy plants.
Deep OT/IT integration
- EtherNet/IP™- or Modbus®-based PLC/PACs can use message instructions to read diagnostic data directly from the radio, reducing downtime during troubleshooting.
- SNMP support for unified IT monitoring; optional OPC Diagnostic Server for long-range wireless SCADA networks.
Security and reliability
- 802.11i, WPA-2 Personal/Enterprise with 128-bit AES encryption, RADIUS authentication.
- VLAN network segmentation, NAT for machine deployment without re-IP’ing, QoS for I/O/video prioritization.
- IGMP snooping & packet filtering to optimize UDP multicast for EtherNet/IP I/O.
- Disaster recovery: configuration stored on a microSD card for fast field replacement.
- Rugged, wide-temperature, shock- and vibration-resistant design.
Easy configuration
- IH Browser graphical software for topology visualization, IP assignment, diagnostics, and remote firmware updates; plus Web UI and SSH.
Application Scenarios
- Factory-floor / discrete manufacturing: AGVs, robotic arms, mobile HMIs, assembly lines.
- SCADA automation & process control: chemical, oil & gas, water treatment, power plants.
- Logistics & warehousing: AS/RS retrieval systems, forklift/stacker communications.
- Mobile worker Wi-Fi infrastructure and asset/RTLS tracking (e.g., AeroScout RTLS signal passing).
- Harsh/outdoor environments: offshore oil platforms and underground mining (weatherproof IP66/IP67 variants).
- Serial-over-wireless: bridging Modbus, DNP3, and similar serial networks over 802.11.
Related Models (RadioLinx RLX2 Family)
- RLX2-IHNF-A — FCC version, standard indoor/outdoor.
- RLX2-IHNF-E — ETSI/RED 3.3 version for Europe.
- RLX2-IHNF-W / -W-A / -W-E / -WC — Weatherproof IP66/IP67 versions for extreme weather and dusty/mining environments.
- RLX2-IHNF-BR — Brazil regulatory variant.
- RLX2-IHNF-Z — Additional regional variant.
- Broader RadioLinx line: earlier 802.11abg hotspots (RLX-IH/RLX2 series) and related ProSoft industrial wireless infrastructure modules.
News, Events & FAQ
Notable points / common questions
- Q: How fast is roaming? A: ProSoft markets “ultra-fast roaming (under 10 ms)” for seamless AP hand-off on moving equipment; the Chinese datasheet cites ≤ 50 ms AP-to-AP switching.
- Q: What data rate can I expect? A: Up to 300 Mbps theoretical (802.11n, MCS7, 40 MHz). Weatherproof variants may show reduced rates.
- Q: How many clients can connect? A: Distributor sources cite roughly 50+ concurrent client connections in AP mode (not an official datasheet figure — treat with caution).
- Q: Is it safe for a plant network? A: Yes — WPA-2 Enterprise, 128-bit AES, RADIUS, VLAN segmentation, and NAT are supported.
- Q: How do I recover a failed unit quickly? A: Use the microSD disaster recovery feature — restore the saved configuration on a replacement radio.
- Q: Outdoor deployments? A: Use the IP66/IP67 weatherproof variants (e.g., -W / -WC).
- Current status: The remains an actively marketed ProSoft/Red Lion product across FCC, ETSI, and weatherproof variants; no official discontinuation notice was found in the sources reviewed.