ELAU PacDrive iSHPS-5 (PS-5 iSH) DC Bus Power Supply, Industrial Automation Spare Part

  1. DB-5 / 13130266-001 (Distribution Box)
  2. iSH070/10025/0-000
  3. iSH090/10040/0-000
  4. iSH110/10060/0-000
  5. C400/A8/1/1/1/00
  6. C600/A8/0/1/0/00
  7. MAX-4/11/03/032/99/1/1/00
  8. MAX-4/11/05/064/99/1/1/00
  9. MC-4/11/05/400
  10. MC-2/11/05/400
  11. SH100/40060/0/1/00
  12. SH30701P02A2000
  13. SM-070/10/0/0/00
  14. SCL055
  15. SCL100
Category: SKU: ELAU iSHPS-5 (PS-5 Brand:

Description

ELAU PacDrive iSHPS-5 (PS-5 iSH) DC Bus Power Supply, Industrial Automation Spare Part

image

iSHPS-5 Power Supply

 

Product Core Overview

The iSHPS-5 (also named PS-5 POWER SUPPLY iSH, part code VPM02D20AA00) is the central DC bus power supply unit for ELAU PacDrive iSH integrated servo axis system. It converts three-phase AC mains into stable intermediate DC bus voltage for iSH servo modules and DB-5 distribution boxes, while integrating SERCOS communication master interface, mains filter and braking chopper function.This power supply is the backbone of distributed iSH servo networks widely used in packaging, converting and printing machinery. It is an end-of-life ELAU spare, stocked for maintenance replacement of legacy PacDrive iSH lines, supporting up to multiple iSH axes via cascaded DB-5 distribution modules. Built-in diagnostic LEDs enable quick fault localisation to reduce machine downtime.

 

Main Technical Specifications

Item Specification
Brand ELAU (Schneider Electric)
Model iSHPS-5 / PS-5 iSH
Part No. VPM02D20AA00
Product Type Intermediate Circuit Power Supply for iSH Servo System
Input Voltage 3 × 400–480 VAC, 50 / 60 Hz
DC Bus Output 270 VDC – 680 VDC intermediate bus
Control Supply 24 VDC auxiliary I/O supply
Communication SERCOS interface for iSH servo bus
Integrated Functions Mains EMC filter, brake chopper, bus diagnostic, enable control
Supported Peripherals DB-5 distribution box, iSH integrated servo motors
Operation Temp. +5 ℃ ~ +45 ℃ (derate above 45 ℃, max +55 ℃)
Ambient Humidity 5%–90% RH, non-condensing
Protection Rating IP20 (cabinet installation)
Mounting DIN rail mounting
Protection Overvoltage, undervoltage, overcurrent, short circuit, over-temperature, earth fault
Application Packaging machines, labelers, slitter rewinders, printing & converting lines

 

Quality Control Procedure

  1. Visual Incoming Inspection: Inspect casing, terminal blocks, status LEDs, Ethernet / SERCOS port, label and serial number integrity.
  2. ESD Controlled Handling: All inspection and testing on grounded ESD workstation with anti-static wrist strap.
  3. Power-on Burn-in Test: Energise control supply and mains input for 4 hours; monitor temperature, fan and indicator status.
  4. DC Bus Output Test: Verify stable intermediate voltage output under no-load condition, check chopper circuit response.
  5. SERCOS Communication Test: Link with PacDrive controller and DB-5 module, validate bus scanning and axis identification.
  6. Enable & Safety Circuit Test: Check inverter enable signals and emergency stop interlock loop.
  7. Firmware Validation: Confirm hardware/firmware revision matches original machine configuration.
  8. Data Archiving: Record serial number and full test log, attach inspection sticker, vacuum anti-static packaging.
  9. Pre-shipment Audit: Double-check model code and part number before dispatch.

 

Recommended Related Models & Order Codes (15pcs)

  1. DB-5 / 13130266-001 (Distribution Box)
  2. iSH070/10025/0-000
  3. iSH090/10040/0-000
  4. iSH110/10060/0-000
  5. C400/A8/1/1/1/00
  6. C600/A8/0/1/0/00
  7. MAX-4/11/03/032/99/1/1/00
  8. MAX-4/11/05/064/99/1/1/00
  9. MC-4/11/05/400
  10. MC-2/11/05/400
  11. SH100/40060/0/1/00
  12. SH30701P02A2000
  13. SM-070/10/0/0/00
  14. SCL055
  15. SCL100

 

Frequently Asked Questions

Q1: What is the difference between iSHPS-5 and regular MAX series power supply?A: iSHPS-5 is exclusively designed for distributed iSH servo axes + DB-5 distribution boxes; MAX drives use separate conventional DC bus architecture, they are not interchangeable.

Q2: Is iSHPS-5 discontinued?A: Yes, ELAU PacDrive iSH system is fully end-of-life. Stock is original surplus or fully tested refurbished spare parts.

Q3: Can I replace this unit hot while the cabinet is live?A: Hot swap is NOT allowed. Perform LOTO, isolate 400V mains and wait minimum 5 minutes for DC bus capacitors to discharge before disassembly. Always measure residual bus voltage.

Q4: Red fault LED on after replacement, what should I check?A: Check 3-phase mains, 24V control supply, SERCOS wiring, DB-5 distribution connections, earth fault and brake resistor. Use PacDrive Software to read fault codes.

Q5: Warranty terms?A: Original surplus new: 12-month warranty. Refurbished tested stock: 6-month warranty. Damage from wrong mains voltage, miswiring, ESD or capacitor ageing abuse is excluded.

Q6: Commissioning software?A: ELAU PacDrive Software (PDS). Original project file with iSH axis topology must be available for commissioning.

 

Installation & Configuration Guide

Pre-installation Preparation

  • Confirm cabinet environment: clean, low dust, no condensation, separate from high-noise frequency drives.
  • Prepare ESD protection, insulated torque screwdriver, SERCOS bus cable, DB-5 boxes and PacDrive project backup.
  • Back up the full machine project before removing the faulty power supply.

Installation Steps

  1. Execute LOTO lockout-tagout, cut off 400V three-phase mains and 24V control supply.
  2. Wait ≥5 minutes for DC bus capacitors to discharge; verify residual voltage below 50V with multimeter.
  3. Disconnect mains terminals, DC bus, SERCOS, enable and 24V control wiring. Release DIN rail latch and remove unit.
  4. Unpack new spare under ESD protection, avoid touching high-voltage PCB components.
  5. Mount iSHPS-5 firmly on DIN rail and lock latch.
  6. Wire three-phase mains, brake resistor, 24V control, SERCOS bus and DB-5 distribution cables strictly per wiring diagram. Separate high-voltage power cables from signal cables.
  7. Tighten all power terminals to specified torque and verify PE protective earth connection.

Configuration & Commissioning

  1. Power up 24V control supply first and check front panel LED status; then apply three-phase mains.
  2. Open PacDrive Software and connect to PacDrive motion controller.
  3. Scan SERCOS network, confirm iSHPS-5, DB-5 boxes and all iSH axes are detected online.
  4. Verify bus topology, axis assignment, motor data and safety enable logic match the saved project.
  5. Run manual jog test for each iSH servo; check rotation direction, encoder feedback and emergency stop.
  6. Test synchronisation, electronic cam and flying shear functions under manual mode.
  7. Clear all alarms after system self-diagnosis passes.
  8. Switch machine back to automatic mode and save commissioning record.

Maintenance Notes

  • Do not remove casing while high voltage is present; internal capacitors hold dangerous charge long after power off.
  • Keep ventilation slots clean; dust build-up triggers over-temperature trips.
  • Do not use liquid cleaners on the unit.
  • Store spare power supply in dry sealed anti-static packaging, avoid vibration and temperature cycling.