Description
Bosch Rexroth R901239533 VT-HACD-3-2X/0-I-00/000 Digital Hydraulic Axis Controller, Industrial Automation Spare Part
Product Core Overview
The VT-HACD-3-2X/0-I-00/000 (Material No. R901239533) is a DIN rail-mounted digital closed-loop control electronics for electro-hydraulic axes from Bosch Rexroth. It adopts a 32-bit PowerPC processor and supports PIDT1 closed-loop control for position, velocity, pressure, force and alternating position/pressure control of hydraulic servo/proportional valves.This variant /0 means no integrated fieldbus interface (basic Ethernet only), programmed via BODAC configuration software. It supports SSI and incremental encoder feedback, built-in signal arithmetic, ramp generation, cam blocks and valve characteristic compensation. Widely used in metal forming, injection molding, test benches, press machines and other high-precision hydraulic equipment.VT-HACD-3 series is end-of-life; the recommended successor platform is Rexroth VT-HMC series. It is supplied as original surplus or fully tested refurbished spare parts for existing hydraulic machine retrofits and maintenanceBosch Rexr….

R901239533 VT-HACD-3-2X/0-I-00/000
Main Technical Specifications
| Item | Specification |
|---|---|
| Brand | Bosch Rexroth |
| Model | VT-HACD-3-2X/0-I-00/000 |
| Material No. | R901239533 |
| Series | VT-HACD-3 2X Digital Hydraulic Axis Controller |
| Product Type | Hydraulic closed-loop axis controller / digital valve amplifier |
| Processor | 32-bit PowerPC |
| Supply Voltage | 18–30 VDC (nominal 24 VDC) |
| Analog Inputs | 6 AI, configurable ±10V / 0–10V / 4–20mA |
| Analog Outputs | 3 AO; AO1: ±10V or 4–20mA switchable; AO2/AO3: ±10V, 14-bit resolution |
| Digital I/O | 16 DI / 16 DO; dedicated enable input + OK status output |
| Position Feedback | Incremental encoder (max 100 kHz), SSI absolute encoder |
| Communication | RS232 for BODAC commissioning, dual Ethernet ports (basic, no fieldbus on this /0 version) |
| Control Algorithm | PIDT1 controller, valve curve correction, dead-zone compensation, zero offset calibration |
| Mounting | DIN rail TH35 |
| Dimension | 65 × 117.5 × 170 mm |
| Weight | Approx. 0.6 kg |
| Operating Temperature | 0 ℃ ~ +50 ℃ |
| Ambient Humidity | 5%–90% RH, non-condensing |
| Protection Rating | IP20 |
| Certification | CE, RoHS |
| Application | Hydraulic press, injection machine, metal forming, hydraulic test bench, servo hydraulic closed-loop system |
Quality Control Procedure
- Visual Incoming Inspection: Check housing, terminal blocks, D-Sub encoder port, Ethernet sockets, label, serial number and PCB condition.
- ESD Controlled Handling: All inspection and testing performed on grounded anti-static workstation with ESD wrist strap.
- Power-on Burn-in Test: 24VDC continuous energisation for 4 hours; monitor status LEDs and operating temperature.
- I/O Functional Test: Verify all analog input range, analog output linearity, digital input/output switching.
- Encoder Interface Test: Connect incremental / SSI encoder, confirm position reading stable.
- Closed-loop Simulation Test: Load existing parameter set, test PID output to simulate proportional valve drive.
- BODAC Communication Test: Connect via RS232, confirm parameter upload/download, diagnostic reading.
- Firmware Compatibility Check: Confirm firmware version matches machine project backup.
- Data Archiving: Record serial number and full test report, attach inspection sticker, vacuum anti-static packaging.
- Pre-shipment Audit: Double-check part number R901239533 and confirm /0 basic variant before dispatch.
Recommended Related Models & Order Codes (15pcs)
- R901239535 VT–2X/E-I-00/000 (EtherNet/IP version)
- R901227616 VT–2X/P-I-00/000 (PROFINET version)
- R9012VT-/N-I-00/000 (PROFIBUS DP version)
- VT-HMC Digital Hydraulic Controller (New replacement series)
- 4WRPEH Servo Proportional Valve
- 4WREE Proportional Directional Valve
- R900777335 BODAC Software Package
- SSI Encoder for Hydraulic Cylinder
- Incremental Encoder
- 24VDC Power Supply
- Shielded encoder cable
- Shielded analog signal cable
- VT-VSPA1 Analog Amplifier
- VT-VRPA2 Amplifier
- HNC100 Hydraulic Controller
Frequently Asked Questions
Q1VT-/0-I-00/000 replace /E /P /N versions directly?A: No. Suffix defines fieldbus interface. This /0 version has no PROFIBUS / PROFINET / EtherNet/IP. Confirm PLC communication architecture before substitution.
Q2: Is this controller discontinued?A:VT- series is end-of-production. New project migration recommendation: VT-HMC series hydraulic axis controller.
Q3: Does this module support hot swap?A: DIN rail power module can be replaced after power cut-off. It is NOT hot-swap while the hydraulic axis is running; axis control, pressure and position loop will drop out. LOTO and machine safety lockout are required.
Q4: Output unstable or valve jitter after installation, what to check?A: Check 24V power quality, shielding grounding, encoder wiring, encoder pulse count, valve offset/dead zone parameter, PID gain and signal cable separation from power cables. Use BODAC to read internal diagnostic logs.
Q5: Warranty terms?A: Original surplus new: 12-month warranty. Refurbished tested stock: 6-month warranty. Damage caused by reverse power, short circuit on analog output, ESD, wrong encoder type, corrupted parameter set is excluded.
Q6: Commissioning software?A: BODAC (R900777335). Full backup of axis parameters, ramp settings, valve curve and PID gains must be saved before replacement.
Installation & Configuration Guide
Pre-installation Preparation
- Confirm cabinet environment: clean, low dust, no condensation, signal wiring separated from high-power hydraulic valve cables.
- Prepare ESD protection, insulated screwdriver, BODAC software, RS232 programming cable, 24V DC power supply and machine parameter backup.
- Execute LOTO, depressurize hydraulic circuit and lock machine.
Installation Steps
- Cut off 24V supply, release DIN rail latch and remove old controller.
- Unpack new spare under ESD protection; avoid touching PCB and terminal pins.
- Clip the unit onto DIN rail and lock.
- Wire 24VDC power, analog command/feedback, digital I/O, encoder and proportional valve drive strictly per wiring drawing.
- Single-point shielding ground for all analog and encoder cables.
Configuration & Commissioning
- Power on and check module OK LED.
- Connect PC via RS232, launch BODAC and go online.
- Restore backup parameter set: scaling, encoder resolution, valve curve, PID, ramp and limit values.
- Perform zero offset calibration, dead zone compensation for the proportional valve.
- Jog axis manually, verify position / pressure closed-loop response, check for oscillation.
- Run single-cycle test, clear all controller alarms after self-diagnosis passes.
- Release machine lock, test automatic cycle and save commissioning log.
Maintenance Notes
- Hydraulic closed-loop parameters are machine-specific; do not copy parameters from other machines arbitrarily.
- Encoder cables must remain shielded and intact; cable damage will cause position drift and jitter.
- Keep ventilation clear; overheating leads to controller reset or unstable control output.
- Store spare controller in dry sealed anti-static packaging.