Description
A6500‑CC | Emerson (AMS Machinery Health)
Title
A6500‑CC Communication Card for AMS 6500 ATG Machinery Health Monitor System

A6500‑CC
Product Description
The Emerson A6500‑CC is a dedicated rack communication interface card designed exclusively for the AMS 6500 ATG machinery protection and condition monitoring platform. It acts as the primary data gateway between the 6500 ATG rack backplane and external supervisory systems, collecting vibration, shaft position, speed, temperature and alarm data from measurement modules inside the rack and transmitting this information to DCS, SCADA, asset management software and host workstations. It supports hot‑swap operation and can be configured for redundant deployment within the 6500 ATG rack, delivering stable, continuous data transmission for critical rotating machinery. This card is a core accessory for API 670 compliant TSI systems, widely paired with A6500‑SR / A6500‑RR / A6500‑FR rack frames, ‑RC relay cards and ‑TP temperature process cards.
Technical Specifications
| Item | Parameter |
|---|---|
| Catalog Number | ‑CC |
| Manufacturer | Emerson |
| Product Series | AMS 6500 ATG Machinery Health Monitor |
| Function | Rack Communication Interface Card |
| Onboard Interfaces | Ethernet, USB |
| Supported Protocols | Modbus TCP, Modbus RTU, OPC UA |
| Rack Compatibility | ‑SR, ‑RR, ‑FR |
| Redundancy Support | Dual communication card redundant configuration available |
| Hot Swap | Yes, hot‑swappable |
| Operating Supply | Powered by rack backplane |
| Operating Temperature | -20°C ~ +65°C |
| Form Factor | Plug‑in rack module for 6500 ATG chassis |
| Lifecycle Status | Mature spare part for installed AMS 6500 ATG fleets |
| Certifications | API 670, CE, DNV marine certification |
| Associated Modules | ‑RC, ‑TP, universal measurement cards |
Key Features & Advantages
- Multi‑Protocol Data Gateway Native Modbus TCP, Modbus RTU and OPC UA support enables seamless integration with mainstream DCS, SCADA and asset management platforms, eliminating custom protocol conversion hardware.
- Redundant Communication Deployment Two ‑CC cards can be installed in one rack for redundant communication paths, removing single points of failure for machine health data transmission in high‑risk assets.
- Hot‑Swappable Maintenance The communication card can be replaced without powering down the entire 6500 ATG rack, reducing planned outage duration and avoiding interruption to machinery protection functions.
- Full Rack Data Acquisition Gathers all measurement values, peakvue diagnostic data, alarm and danger status signals from every monitoring channel inside the rack for centralized host viewing and trending.
- Marine & Harsh Environment Qualified Available with DNV marine approval, suitable for offshore platforms, marine propulsion machinery and onshore heavy process plants with vibration and temperature fluctuations.
- Built‑in Diagnostics & Status Indication Front‑panel LEDs display network link, communication activity and card health status. Internal fault diagnostics report link loss, backplane communication failure and configuration errors to the host system.
Typical Applications
Steam turbines, centrifugal compressors, generators, large process pumps, blowers and fans, offshore oil & gas rotating equipment, marine propulsion machinery, refinery and petrochemical TSI retrofits, power plant machinery condition monitoring.
Brand History (Emerson AMS Machinery Health)
Emerson’s AMS Machinery Health product line inherits the technology from the well‑known Bently Nevada machinery monitoring ecosystem after Emerson’s continuous investment in predictive maintenance and TSI platforms. The AMS 6500 ATG was developed as a modern, scalable rack‑based machinery health monitor, designed to satisfy API 670 protection requirements while integrating modern digital communication protocols for Industry 4.0 asset health management. The 6500 ATG family expands the portfolio beyond traditional protection, adding advanced predictive diagnostics such as PeakVue for early bearing fault detection. Emerson continues to provide spare parts, calibration and repair support for the AMS 6500 ATG installed base alongside the newer AMS Asset Monitor portfolio.
Related News & Events
‑CC remains a frequently stocked critical spare for sites operating AMS 6500 ATG racks. Many EPCs and end users specify this communication card during brownfield TSI upgrades and rack expansion projects. Emerson periodically releases firmware updates for ‑CC to improve OPC UA stability and Modbus interoperability with newer DCS releases. While Emerson promotes compact next‑generation monitoring hardware for new greenfield projects, the 6500 ATG platform including ‑CC is still widely accepted in oil & gas and power sectors due to its API 670 compliance and proven field reliability.
Short Sales Blurb (for quotation / product list)
‑CC Emerson AMS 6500 ATG Communication Card, Ethernet & USB interface, Modbus TCP / RTU / OPC UA, hot‑swappable, redundant capable, API 670 TSI rack communication gateway for turbine, compressor and generator condition monitoring.