A6500-UM, Emerson EPRO AMS 6500 ATG Universal Measurement Card, Multi-sensor vibration & position monitoring module

Model Order Number Description
Communication Card A6500-CC Modbus TCP / RTU comm card for A6500 rack
LVDT Conditioner A6500-LC LVDT interface module, works with A6500-UM
Speed / Keyphasor Card A6500-SM Dedicated speed and overspeed monitor card
System Rack A6500-XR AMS6500 rack chassis
Rack Power Supply A6500-PS Rack power module
3300 Proximity Probe 330104 Eddy current probe
Probe Extension Cable 330730 Probe extension cable
Piezo Accelerometer A6500-ACC EPRO vibration accelerometer
Sensor BNC Buffered Output Cable A6500-CAB-BUF Buffered signal test cable
Configuration Software AMS6500-CFG AMS 6500 programming tool
Diagnostic Software SYSTEM1 Emerson asset condition monitoring platform
Rack Backplane A6500-BP A6500-xR backplane
Front Panel Label Kit A6500-LABEL Custom alarm label set
A6500-SR Rack variant A6500-SR Compact rack version
Terminal Cable A6500-CAB-TERM Field wiring terminal cable
Category: SKU: A6500-UM, EPRO Brand:

Description

A6500-UM, Emerson EPRO AMS 6500 ATG Universal Measurement Card, Multi-sensor vibration & position monitoring module

 

Core Product Introduction

The A6500-UM is a universal measurement card for Emerson AMS 6500 ATG machinery protection and condition monitoring rack system (A6500-xR rack). It is a multi-type signal acquisition board supporting a wide range of rotating machinery sensors: eddy-current proximity probes, piezoelectric accelerometers/velocity transducers, seismic sensors, low-frequency bearing vibration sensors, Hall-effect speed pickups, and LVDT (paired with A6500-LC). It has 2 independent dynamic sensor channels, 5 digital inputs, 6 digital alarm outputs and isolated 4/0–20mA analog outputs. It communicates to the A6500-CC communication card via internal RS485 backplane bus, then converts to Modbus TCP / Modbus RTU for host DCS, SCADA or System 1 diagnostic software. Widely used on steam turbines, gas turbines, centrifugal compressors, pumps and fans in power, oil & gas and petrochemical plants for vibration, thrust, eccentricity, speed and dynamic pressure protection monitoringEmerson.

A6500-UM

Main Technical Specifications

Item Parameter
Part Number A6500-UM
Manufacturer Emerson (EPRO / CSI)
Platform AMS 6500 ATG (-xR rack)
Main Sensor Channels 2 universal dynamic input channels
Supported Sensors Eddy current, piezo accelerometer/velometer, seismic, LF vibration, Hall, LVDT (-LC required)
Digital Inputs 5 DI
Digital Outputs 6 configurable relay/alarm DO
Analog Outputs Isolated 0/4–20 mA
Internal Bus RS485 to -CC Comms Card
Host Protocols (via CC) Modbus TCP, Modbus RTU
Bandwidth Up to 18,750 Hz (eddy current mode)
Operating Temperature -20 °C ~ +70 °C
Storage Temperature -40 °C ~ +85 °C
Humidity 5%–95% RH, non-condensing
Shock / Vibration IEC 60068-2 compliant
Mounting Plug-in into -xR rack
Hot Swap Supported
Certifications CE, cULus
Lifecycle Status Mature, spare stock available
Weight ~0.20 kg

 

Quality Control Procedure

  1. Visual & Label Inspection: Verify Emerson/EPRO marking, -UM part number, serial number, edge connector pins, front panel status LEDs; no damage or corrosion.
  2. Rack Power Boot Test: Insert into -xR rack, power on, confirm self-test, PWR and STATUS LEDs normal, no overheating.
  3. Channel Mode Configuration: Switch between eddy current, piezo, seismic, LF modes via PC configuration software.
  4. Eddy Current Channel Test: Check -24V probe excitation, inject gap signal, verify gap & vibration reading and cable break detection.
  5. Piezo / Seismic Channel Test: Simulate vibration signal, check acceleration/velocity amplitude and frequency response.
  6. DI & DO Test: Trigger digital inputs, verify relay alarm outputs for alert / danger states.
  7. 4–20mA Analog Output Test: Check linear isolated analog output for vibration or speed values.
  8. Backplane Communication Test: Communicate with -CC, confirm data forwarding to Modbus master.
  9. Fault Diagnostic Simulation: Simulate sensor open, short, out-of-range; verify fault flag and alarm response.
  10. Packaging & Traceability: Anti-static packaging, foam protection, serial-number QC report before shipment.

 

Frequently Asked Questions (FAQ)

Q1: What rack does -UM fit into?A1: It installs in -xR series rack; the system requires an -CC communication card for Modbus TCP/RTU external communication.

Q2: Does -UM support LVDT directly?A2: No. LVDT measurement needs the companion -LC LVDT conditioner module.

Q3: What software is used to core ?A3: Emerson AMS 6500 configuration software; diagnostics and trending can also be viewed in System 1.

Q4: Is it compatible with Bently 3500 system?A4: No. AMS 6500 ATG is Emerson EPRO platform, different hardware & backplane from Bently Nevada 3500.

Q5: Can it be hot swapped?A5: Hot-swap supported. During replacement, the two measurement channels lose monitoring; MOC and alarm bypass are mandatory for protection applications.

Q6: What is the difference en and -SM? = universal multi-sensor cA6500-SM is dedicated speed / keyphasor card for overspeed monitoring.

 

Installation & Configuration Guide

  1. Pre-install Preparation: -xR rack, -CC comms card, 24VDC rack power, sensor cables, configuration PC.
  2. Module Insertionug into empty rack slot, lock the retention screw.
  3. Field Sensor Wiring: Connect proximity, piezo or speed sensors to front terminals; separate low-level sensor cables from high-power VFD cables.
  4. Power Up: Energize rack power, wait for card self-test, confirm no sensor fault alarms.
  5. Channel Setup: Assign sensor type, measurement unit, alarm setpoints (Alert / Danger), filter and bandwidth.
  6. Analog & Relay Mapping: Assign 4–20mA outputs and DO relays to vibration, gap or speed alarms.
  7. -CC Communication Setup: Configure Modbus TCP/RTU address map for DCS/SCADA.
  8. Sensor Calibration: Perform probe gap calibration or vibration reference calibration as required.
  9. Online Commissioning: Monitor live waveforms, spectrum, alarm status and raw buffered signals.
  10. Backup: Save the complete AMS 6500 project including all channel parameters and alarm settings.

Warning: This card is used for machinery protection. Improper wiring, wrong sensor type or un-bypassed alarm during replacement may lead to false trip or loss of machine protection.

 

Related AMS 6500 ATG Series Models & Accessories (15 pcs)

Model Order Number Description
Communication Card Modbus TCP / RTU comm card for rack
LVDT Conditioner -LC LVDT interface module, worth
Speed / Keyphasor Card -SM Dedicated speed and overspeed monitor card
System Rack -XR AMS6500 rack chassis
Rack Power Supply -PS Rack power module
3300 Proximity Probe 330104 Eddy current probe
Probe Extension Cable 330730 Probe extension cable
Piezo Accelerometer -ACC EPRO vibration accelerometer
Sensor BNC Buffered Output Cable -CAB-BUF Buffered signal test cable
Configuration Software AMS6500-CFG AMS 6500 programming tool
Diagnostic Software SYSTEM1 Emerson asset condition monitoring platform
Rack Backplane -BP -xR backplane
Front Panel Label Kit -LABEL Custom alarm label set
-SR Rack variant -SR Compact rack version
Terminal Cable -CAB-TERM Field wiring terminal cable