05704-A-0145 | Honeywell Zellweger

  1. Four‑Channel 4–20mA Universal Gas Input Compatible with most industry standard 4–20mA gas transmitters, covering toxic, oxygen and infrared flammable gas measurement, flexible for mixed gas monitoring layouts.
  2. On‑board Local Display & LED Status Real‑time concentration reading and channel status visible on the front LCD, allowing field technicians to check readings and alarms without connecting to a host PC.
  3. Multi‑Tier Alarm & Comprehensive Loop Diagnostics Supports configurable alarm thresholds and continuous wiring fault detection. It identifies open or shorted field loops and sensor failures to avoid blind monitoring.
  4. Remote Control Functions Remote alarm reset and remote inhibit enable central control room operation, convenient for safety system interlock and maintenance lockout workflows.
  5. Modular System 57 Rack Architecture Works together with relay cards and backplane assemblies, supporting incremental expansion of gas points in the same rack. Easy hot‑swap replacement during plant maintenance.
  6. Proven Safety‑Oriented Design Built for hazardous area gas safety monitoring, widely accepted in oil & gas and chemical sites for fixed gas detection and emergency shutdown interlock.
Category: SKU: 05704-A-0145 Brand:

Description

05704-A-0145 | Honeywell Zellweger

 

Title

05704-A-0145 Four‑Channel 4–20mA Input Control Card for System 57 Gas Detection Rack

 

Product Description

The Honeywell Zellweger 05704-A-0145 is a microprocessor‑based plug‑in control card designed exclusively for the legacy System 57 / 5704 rack‑mounted gas detection system. It receives four independent 4–20 mA analog signals from field gas transmitters, including toxic gas, oxygen, infrared combustible and other loop‑powered gas sensors. The module performs continuous gas concentration measurement, multi‑level alarm judgment, loop fault detection and local status display via the front LCD and channel LEDs. It communicates alarm and diagnostic data through the rack backplane to relay output cards and the central host system. This card supports remote reset, alarm inhibit and fault reporting functions, and is widely used as a core monitoring card for fixed gas safety systems in hazardous process areas. It is the 4–20mA counterpart to the catalytic sensor variant 05704-A-0144.

05704-A-0145

Technical Specifications

Item Parameter
Catalog Number 05704-A-0145
Manufacturer Honeywell Zellweger Analytics
Platform System 57 / 5704 Gas Detection Rack
Channel Count 4 independent 4–20 mA input channels
Supported Sensors Toxic gas, O2, IR hydrocarbon transmitters with 4–20mA output
Front Panel LCD display + per-channel status LED indicators
Alarm Levels Configurable A1 / A2 / A3 gas alarms, fault alarm
Diagnostics Open loop, short circuit, sensor fault monitoring
Functions Remote alarm reset, remote inhibit
Supply Powered by rack backplane
Form Factor Rack plug‑in module for System 57 chassis
Operating Temperature 0°C ~ +60°C
Dimensions 133 × 25 × 175 mm
Weight Approx. 0.165 kg
Lifecycle Status Obsolete, spare part only
Certifications CE, IECEx, ATEX compliant for gas safety systems
Matching Accessories 05704-A-0121 quad relay interface card

 

Key Features & Advantages

  1. Four‑Channel 4–20mA Universal Gas Input Compatible with most industry standard 4–20mA gas transmitters, covering toxic, oxygen and infrared flammable gas measurement, flexible for mixed gas monitoring layouts.
  2. On‑board Local Display & LED Status Real‑time concentration reading and channel status visible on the front LCD, allowing field technicians to check readings and alarms without connecting to a host PC.
  3. Multi‑Tier Alarm & Comprehensive Loop Diagnostics Supports configurable alarm thresholds and continuous wiring fault detection. It identifies open or shorted field loops and sensor failures to avoid blind monitoring.
  4. Remote Control Functions Remote alarm reset and remote inhibit enable central control room operation, convenient for safety system interlock and maintenance lockout workflows.
  5. Modular System 57 Rack Architecture Works together with relay cards and backplane assemblies, supporting incremental expansion of gas points in the same rack. Easy hot‑swap replacement during plant maintenance.
  6. Proven Safety‑Oriented Design Built for hazardous area gas safety monitoring, widely accepted in oil & gas and chemical sites for fixed gas detection and emergency shutdown interlock.

 

Typical Applications

Offshore platforms, refineries, petrochemical plants, chemical processing, natural gas terminals, wastewater chlorine monitoring, compressor stations, legacy System 57 gas detection rack retrofit and spare inventory.

 

Brand History (Honeywell Zellweger Analytics)

Zellweger Analytics was a leading specialist in fixed gas and flame detection. It was acquired by Honeywell and integrated into Honeywell Analytics, forming the core gas safety product portfolio. The System 57 series was a classic rack‑based centralized gas detection platform launched decades ago, popular for multi‑point gas monitoring in large process plants. Honeywell later introduced modern standalone gas controllers and networked systems to replace System 57 for new greenfield projects.

 

Related News & Events

The 05704-A-0145 has been discontinued by Honeywell for new sales. Current demand comes almost entirely from end users maintaining existing System 57 gas safety racks. Many refineries and offshore facilities keep tested spare cards on hand to avoid gas detection system outage. During safety system upgrade projects, owners often migrate from System 57 to newer Honeywell gas controllers while stocking limited 05704-A-0145 modules to extend service life before full decommissioning. Honeywell still provides limited technical documentation support for the installed base.

Short Sales Blurb (for quotation / product list)

05704-A-0145 Honeywell Zellweger 4‑Channel 4–20mA Gas Detection Control Card for System 57 rack, LCD local display, multi-level alarm & loop fault diagnosis, legacy spare for fixed toxic / flammable gas safety monitoring.