Bently Nevada 3500/15 106M1081-01 Universal AC Power Input Module (PIM), Front-End AC Interface for 3500 Machinery Protection Rack Power Supply Assembly, Paired with 106M1079-01 DC Converter Module
Bently Nevada 3500/15 106M1081-01 Universal AC Power Input Module (PIM), Front-End AC Interface for 3500 Machinery Protection Rack Power Supply Assembly, Paired with 106M1079-01 DC Converter Module
Technical Specifications
Catalog Number: 106M1081-01
Brand: Bently Nevada (Baker Hughes)
Product Type: Half-height universal AC power input module (PIM) for 3500/15
Mating module: 106M1079-01 (DC power converter, installed behind this PIM)
AC Input: 85 ~ 264 VAC, 47–63 Hz, worldwide universal input
Input Terminals: Screw terminals for mains L, N, PE
Output to converter: Internal dedicated power bus to 106M1079-01
Hot Swap: Permitted only in fully redundant dual power configuration
Status Indicator: Front panel “SUPPLY OK” shared status LED
Protection: Input surge, inrush limiting, reverse polarity protection, overvoltage suppression
Mounting: Front half-height dedicated power slot on far left side of standard 3500 chassis
Operating Temperature: -20 °C ~ +60 °C (-4 °F ~ +140 °F)
Humidity: 5%–95% RH, non‑condensing
Compliance: API 670, CE, industrial EMC, Class I Div 2 hazardous area approval
Lifecycle Status: Mature active spare part for 3500 legacy TSI racks
Country of Origin: USA
Weight: ~0.9 kg
Key Features & Advantages
Universal AC front-end PIM : Accepts both 110 VAC and 220–240 VAC plant power without jumper adjustment.
Must work as a matched set : 106M1081-01 cannot operate alone; it requires 106M1079-01 converter behind it to form a complete 3500/15 AC supply.
Redundant architecture support : Two full assemblies can run in parallel for uninterrupted power to safety-critical machinery protection.
Hot-swap capability : Online replacement available when the second redundant power group remains healthy.
EMI filtering built-in : Reduces mains noise before feeding the DC converter, protecting sensitive proximity and vibration monitor channels.
System diagnostic integration : Supply health signal is available locally and in 3500 configuration software / System 1 for remote alarm notification.
New generation 3500/15 PIM : Not interchangeable with older 125840 series PIM for the obsolete 127610-01 converter.
Standard 3500 half-height form : Direct drop-in upgrade/replacement for racks originally fitted with universal AC 3500/15 supply.
Application Fields
Gas turbine, steam turbine and centrifugal compressor machinery protection cabinets
Refinery, pipeline, offshore and LNG rotating equipment TSI monitoring systems
Power plant boiler feed pump, generator and large fan vibration protection racks
Petrochemical expander, refrigeration compressor and process pump condition monitoring
Steel mill, pulp & paper critical rotating machinery protection
Retrofit spare replacement for 3500 racks using universal AC 3500/15 power assemblies
API 670 compliant safety machinery protection systems
Related Product Recommendations
106M1079-01: Matching DC converter module
125840-01 / 125840-02: Old generation AC PIM variants (obsolete)
133300-01 +133292-01: 3500/15 DC power supply set
3500/42M: Vibration and position monitor
3500/45: Accelerometer monitor
3500/53: Relay output module
3500/92: Ethernet communication gateway
3500 rack chassis and backplane
System 1 condition monitoring software
AC input surge protection terminal block
Installation & Maintenance
Installation
Power down the rack unless performing approved redundant hot-swap operation.
Install 106M1081-01 into the front half-height power slot; the rear adjacent slot must be fitted with 106M1079-01.
Torque AC input terminals properly; verify input voltage is within 85–264 VAC before energizing.
Route AC mains cable separately from proximity probe coax, accelerometer and low-level sensor cables to avoid EMI interference.
For redundant design, connect two independent AC power sources to two separate 3500/15 assemblies.
After power-up, confirm “SUPPLY OK” LED and power health status inside the 3500 software.
Do not pair this PIM with legacy 127610-01 converter; they are electrically incompatible.
Ensure cabinet airflow is not blocked to avoid thermal shutdown.
Maintenance
During turnaround inspection, check AC terminals for tightness, cable insulation damage and dust accumulation.
Monitor power alarms in System 1; intermittent supply faults often come from loose mains connections or degraded PIM.
Periodically test redundant switchover by isolating one AC feed while the other supply remains online.
For spare stocking, keep 106M1081-01 together with its matching 106M1079-01 as a complete assembly.
If hot-swap is executed, follow site LOTO and safety permit procedures strictly.
After replacement, verify all monitor channels, relay trip chains and communication are stable.
No field-serviceable internal parts; do not open the module housing.
Record serial numbers, power topology and redundant test results in TSI asset records.