SR469-P5-HI-A20 Product Introduction

SR469-P5-HI-A20 protects critical medium-voltage auxiliary motors in combined-cycle power plants, refineries, chemical and mining facilities. Typical loads include boiler feed pumps, forced draft fans, compressors and large process motors. It serves as a high-priority spare for planned shutdowns, motor protection relay obsolescence replacement and retrofits of existing Multilin 469 protection schemes.

Category: SKU: SR469-P5-HI-A20 Brand:

Description

SR469-P5-HI-A20 Product Introduction

 

Overview

The SR469-P5-HI-A20 is a microprocessor-based Motor Management Relay from GE Multilin (GE Vernova), belonging to the 469 series. It delivers integrated protection, metering, control, temperature monitoring and fault diagnostics for medium-voltage AC motors widely used in power generation, oil & gas and heavy industrial plants. This specific variant features 5A phase CT secondary inputs, multi-range control power and four 4–20 mA analog outputs. It adopts draw-out construction for fast replacement during outages. The original OEM production has been discontinued; it is mainly supplied as surplus or refurbished spare for legacy system maintenance and direct replacement.

SR469-P5-HI-A20

Key Features & Benefits

  • Advanced dynamic thermal motor model with RTD biasing, supporting hot/cold stall limits, cooling time constant setup and start inhibit logic
  • Comprehensive motor protection functions: overload, locked rotor, phase unbalance, loss of phase, ground fault, overvoltage / undervoltage, broken rotor bar detection
  • Built-in waveform capture, event recorder and data logging for post-fault root-cause analysis
  • Local 40-character LCD display and keypad for on-site viewing, parameter setting and testing
  • Dual serial communication: front RS-232 port for local commissioning, rear RS-485 supporting Modbus RTU / DNP3 for SCADA or DCS interconnection
  • Four configurable 4–20 mA analog outputs for transmitting current, voltage, temperature and load metrics
  • Draw-out pluggable design, enabling quick unit swap without full wiring removal
  • Firmware field-upgradable via GE EnerVista software
  • Rugged metal enclosure, optional conformal coating for corrosive cabinet environments

 

Technical Specifications

Item Description
Manufacturer GE Multilin / GE Vernova
Model SR469-P5-HI-A20
Type Medium Voltage Motor Management Relay
Phase CT Secondary 5 A
Control Power 70–265 VAC / 90–300 VDC, 48–62 Hz
Analog Output 4 channels, 4–20 mA
Communication RS232 (front), RS485 (Modbus RTU, DNP3)
Sensor Input Multiple RTD inputs for stator / bearing temperature
VT Connection Delta or wye voltage transformer configuration supported
Mounting Panel / 19-inch rack, draw-out module
OEM Status Discontinued, available as surplus / refurbished spare
Application Medium voltage motor protection, power plant auxiliary drives, compressor, pump, fan motors

 

Typical Applications

SR469-P5-HI-A20 protects critical medium-voltage auxiliary motors in combined-cycle power plants, refineries, chemical and mining facilities. Typical loads include boiler feed pumps, forced draft fans, compressors and large process motors. It serves as a high-priority spare for planned shutdowns, motor protection relay obsolescence replacement and retrofits of existing Multilin 469 protection schemes.

 

Matching Companion & Upgrade Reference

  • Configuration Software: EnerVista 469 Setup
  • Newer replacement series: Multilin 859 / 869 motor relays
  • Current transformers, voltage transformers and RTD sensor assemblies

 

Operation Notes

Verify CT ratio, VT wiring, motor nameplate parameters and protection curve settings before commissioning. The relay settings must be coordinated with upstream protective devices. Back up all configuration files before swapping. Use EnerVista for firmware upgrade and offline simulation testing.

 

FAQ

Q: What is the difference between SR469-P5-HI-A20 and SR469-P5-HI-A20-E? A: The -E suffix denotes updated hardware revision and enclosure; core protection algorithms are similar, but pin assignment and mechanical housing differ. Direct replacement must be validated against panel cutout, wiring schedule and setting file compatibility.

Q: Can it communicate with DeltaV DCS? A: Yes, via Modbus RTU over RS485 with proper DeltaV serial interface mapping. It is not a native DeltaV module.

Q: Can it replace other Multilin motor relays such as 369? A: Not directly. Protection logic, I/O layout and thermal modeling are different; coordination and wiring require full re-engineering.