Description
RS-FS-9001 Product Introduction
Overview
The RS-FS-9001 (Flame Tracker) is a SiC UV flame sensor manufactured by Reuter-Stokes (GE Vernova). It is a two-wire 4–20 mA flame detector designed for gas turbine and boiler burner flame supervision, widely matched with GE Speedtronic turbine control systems. It uses silicon carbide UV photodiode sensing technology with a sapphire viewing window, suitable for high-temperature burner installations, and supports air-cooled or water-cooled accessory options for extreme heat environments.

RS-FS-9001
Key Features & Benefits
- SiC ultraviolet sensing element, excellent resistance to high ambient temperature, insensitive to visible light interference
- 2-wire 4–20 mA loop-powered output; flame strength is proportional to the analog signal
- Hermetically sealed sensor chamber filled with dry argon gas for long service life
- Sapphire optical window, resistant to high temperature and soot erosion
- Auto-gain adjustment, avoids signal saturation under strong flame radiation
- Built-in optical path contamination self-check function for lens fouling diagnosis
- Stainless steel threaded housing, suitable for direct mounting on burner viewport
- ATEX / IECEx hazardous area certification for combustion zone installation
- Compatible with GE Speedtronic Mark VI / Mark VIe TMR turbine safety logic
Technical Specifications
| Item | Description |
|---|---|
| Manufacturer | Reuter-Stokes / GE Vernova |
| Model | RS-FS-9001 |
| Type | SiC UV Flame Sensor (Flame Tracker) |
| Power & Signal | 2-wire loop, 12–30 VDC supply, 4–20 mA output |
| Sensing Band | Ultraviolet UV (SiC photodiode) |
| Max sensor tip temperature | 150°C; cooling accessory required for higher temperature |
| Cooling option | Air cooling or water cooling coil (PN:353B3490G001) |
| Enclosure Material | Stainless steel |
| Protection | IP65 |
| Certification | ATEX, IECEx |
| OEM Status | Active / available as new, surplus, refurbished spare |
| Application | Gas turbine, boiler, industrial burner flame monitoring |
Typical Applications
RS-FS-9001 is the standard flame sensing spare for GE gas turbine units in combined-cycle power plants. It sends flame strength signals to Speedtronic turbine controllers to confirm ignition success and monitor continuous combustion; loss of flame signal will trigger fuel trip protection. It is also widely used for large boiler burner supervision in captive power plants and refineries.
Matching Companion Items
- GE Speedtronic Mark VI / VIe turbine control system
- Water cooling coil assembly 353B3490G001
- Flame signal amplifier / AI input modules
- Burner sight pipe, purge air fitting
Operation Notes
The 4–20mA loop must be wired correctly with proper load resistance. The viewing window needs regular purge air to prevent soot buildup. When ambient temperature exceeds 150°C, cooling kit is mandatory. Verify signal threshold setting in turbine logic after replacement.
FAQ
Q: Can RS-FS-9001 replace Honeywell C7027 UV sensor? A: Not drop-in. Different output interface, spectral response and mechanical thread; control logic configuration needs modification.
Q: Is it a native module for DeltaV or Experion DCS? A: No. It outputs 4–20mA analog signal and connects to DCS AI modules; it is mainly designed for turbine burner safety control.
Q: Does it need separate power supply? A: No, it is loop-powered two-wire device, power and signal share the same pair of wires.