Honeywell FC-QPP-0001 V1.3 Safety Manager Quad Processor Pack (Conformal Coated)

  1. FS-QPP-0001 V1.3 – Standard non-conformal coated Quad Processor Pack
  2. FC-QPP-0001 V1.4 – Updated firmware version QPP
  3. QPP-0002 – Second-generation enhanced quad processor pack
  4. BKM-0001 – Backup memory battery module
  5. FC-SAI-1620M – 16-channel analog input safety module
  6. FC-SDO-0824 – 8-channel safety digital output module
  7. FC-SDI-1624 – 16-channel safety digital input module
  8. FC-PSU-2405 – Safety Manager rack power supply
  9. FC-TPS-0001 – Terminal protection module
  10. SM-TOOLKIT – Safety Manager FLD configuration software package
Category: SKU: Honeywell FC-QPP-0001 V1.3 Brand:

Description

Honeywell FC-QPP-0001 V1.3 Safety Manager Quad Processor Pack (Conformal Coated)

 

Product Introduction

The FC-QPP-0001 V1.3 is the core safety processor module for Honeywell Safety Manager safety instrumented system (SIS). This conformal-coated QPP pack adopts dual-processor, dual-memory fault-tolerant architecture, executing safety logic configured via Functional Logic Diagram (FLD) software, reading field I/O signals and driving safety outputs for ESD and safety interlock protectionMade-in-Ch…. It supports simplex or redundant controller configuration; a dedicated high-speed sync link synchronizes data between paired QPP modules for bumpless switchover. Continuous self-testing, cross-comparison and built-in comprehensive diagnostics help detect hardware faults, communication failures and abnormal process conditions in real time. The conformal coating protects PCB circuits against moisture, dust, corrosive gas and condensation, making it suitable for offshore and aggressive industrial environments. It meets SIL3 safety requirements and is widely used for maintaining legacy Honeywell Safety Manager safety racks.

FC-QPP-0001

Specification Parameters

Item Specification
Brand Honeywell
Model FC-QPP-0001 V1.3
Series Safety Manager SIS
Variant Conformal coated (FS-QPP-0001 V1.3 = non-coated version)
Architecture Dual processor + dual memory, hardware comparison logic
Safety Level SIL3 certified
Form Factor Rack slot module for Safety Manager controller chassis
Operation Mode Simplex / Redundant hot standby
Local Interface Front panel status LCD, status LEDs, mode key switch
Memory Flash + battery-backed SRAM (battery on BKM-0001 module)
Diagnostics Module self-test, cross-check, fault reporting
Operating Temperature -20 °C ~ +60 °C
Humidity 5%–95% non-condensing
Certifications TÜV, FM, UL, CE
Dimension 176 × 88.5 × 212 mm
Weight Approx. 1.3 kg

 

Application Scenarios

  • Oil & gas ESD emergency shutdown systems
  • Refinery and chemical plant safety interlock control
  • Power plant boiler & turbine safety protection
  • Offshore platform and marine safety instrumented systems
  • Pipeline overpressure protection and fire & gas (F&G) control
  • Petrochemical SIS retrofit and spare replacement
  • Fertilizer and hazardous chemical process safety control

 

Recommended 10 Related Models

  1. FS-QPP-0001 V1.3 – Standard non-conformal coated Quad Processor Pack
  2. FC-QPP-0001 V1.4 – Updated firmware version QPP
  3. QPP-0002 – Second-generation enhanced quad processor pack
  4. BKM-0001 – Backup memory battery module
  5. FC-SAI-1620M – 16-channel analog input safety module
  6. FC-SDO-0824 – 8-channel safety digital output module
  7. FC-SDI-1624 – 16-channel safety digital input module
  8. FC-PSU-2405 – Safety Manager rack power supply
  9. FC-TPS-0001 – Terminal protection module
  10. SM-TOOLKIT – Safety Manager FLD configuration software package

 

FAQ

Q1: What is the difference between FC- and FS-? A1: FC version is conformal coated for corrosive, humid, offshore environments. FS is standard non-coated for ordinary indoor control rooms. Both share identical logic and pin compatibility.

Q2: Does FC- V1.3 support SIL3? A2: Yes, the Safety Manager system with properly configured redundant QPP architecture achieves SIL3 compliance per TÜV certification. Installation and application must follow Honeywell safety manual.

Q3: Can two FC- V1.3 run as redundant pair? A3: Yes. A dedicated redundant communication link synchronizes states. Fault of primary processor triggers automatic bumpless transfer to standby module without tripping safety logic.

Q4: Is this module hot-swappable? A4: It can be replaced online under specific maintenance procedures for redundant racks. For simplex controller configuration, rack power down is required. Always lock out safety functions before removal.

Q5: Is FC- V1.3 still in active production? A5: It belongs to legacy Safety Manager hardware. New original production has been phased out; available stock is new surplus or fully tested refurbished spare units for system maintenance.

Q6: Where is the backup battery for SRAM located? A6: The battery is integrated on the separate BKM-0001 battery module, not inside the QPP pack itself. Replace the battery periodically to avoid losing logic and retention data.