Description
GE 369-LO-R957805E 369 Motor Management Relay
Product Introduction
The 369-LO-R957805E is a multi-function motor management protection relay from GE, designed for comprehensive monitoring, protection and control of medium and low-voltage three-phase induction motors. It integrates motor protection, metering, fault recording, logic control and communication functions in a compact panel-mount housing. This relay delivers full protection suite including overload, locked rotor, phase loss, phase unbalance, overvoltage, undervoltage, earth fault and thermistor protection. It is equipped with front HMI keypad and display for local parameter configuration, status reading and fault review. Communication interfaces consist of 1 × front RS232 port and 3 × rear RS485 ports, supporting Modbus RTU protocol. Users can also configure, monitor and retrieve fault records remotely via EnerVista 369 software. Widely adopted for critical motor assets, it reduces motor burnout risk, provides event logs for root-cause analysis, and seamlessly connects to SCADA and DCS systems.

GE 369-LO-R957805E
Specification Parameters
| Item | Specification |
|---|---|
| Brand | GE (General Electric) |
| Model | 369-LO-R957805E |
| Product Family | 369 Motor Management Relay |
| Mounting | Panel cutout mounting |
| Display & Control | Local LCD display + membrane keypad |
| Communication | 1 × RS232 (front), 3 × RS485 (rear), Modbus RTU |
| Protection Functions | Overload, locked rotor, phase loss, phase unbalance, earth fault, OV/UV, RTD/PTC thermistor |
| Metering | Current, voltage, power, power factor, energy, run hours |
| Data Recording | Fault event log, oscillography / disturbance record |
| Auxiliary Supply | Wide-range AC/DC auxiliary power |
| Operating Temperature | -40 °C ~ +70 °C |
| Certifications | UL, CSA, CE |
| Housing Protection | Front panel IP54, rear terminal IP20 |
| Software | EnerVista 369 |
Application Scenarios
- Water pump and blower motor protection in water & wastewater plants
- Conveyor, crusher and feeder motors for mining & aggregate processing
- Compressor, pump and fan motors for oil & gas and refinery facilities
- Auxiliary motors of thermal power plants
- Chemical process motor control and protection cabinets
- Pulp & paper production line motor assets
- HVAC large motor protection for commercial and industrial buildings
- Retrofit replacement for existing GE 369 relay installations
Recommended 10 Related Models
- 369-HI-R-M-0-0-0-E
- 369-HI-R-0-0-0-0-E
- 369-LO-R-M-0-0-0-E
- 369-LO-R-0-0-0-0-E
- 369-HI-0-M-0-0-0-E
- 369-HI-0-R-0-0-0-E
- 469-P5-HI-A20-E – Feeder & Motor Relay
- 489-P5-LO-A20-E – Generator Management Relay
- 745-W2-P5-G5-HI – Transformer Protection Relay
- Multilin 350 – Feeder Protection Relay
FAQ
Q1: What does LO mean in 369-LO-R957805E? A1: LO indicates the standard I/O configuration variant of the 369 series, while HI stands for the high I/O version with more digital inputs and relay outputs.
Q2: Can this relay connect to EnerVista software? A2: Yes. It supports connection through the front RS232 or rear RS485 Modbus RTU port. EnerVista 369 is used for setting upload/download, fault waveform analysis and asset trending.
Q3: Is the 369 series still in active production? A3: The GE Multilin 369 motor relay is an end-of-life legacy product. Available stock is new surplus or fully tested refurbished spare units for maintenance and replacement.
Q4: Does it support RTD / PTC thermistor input? A4: Yes, it accepts motor winding temperature sensors for thermal protection, which is critical for high-duty-cycle motors.
Q5: Can multiple 369 relays share one RS485 Modbus bus? A5: Yes. Each relay can be assigned a unique Modbus address, allowing multi-drop connection to SCADA or PLC host systems.
Q6: Is it suitable for VFD-fed motors? A6: It can be applied for VFD output side monitoring with proper settings; verify harmonic impact and CT/VT arrangement before commissioning.