Emerson KJ3002X1-BC1 DeltaV M‑Series 8‑Channel Analog Input Module (VE4003S1B2 / 12P0681X072)

  1. KJ3002X1-BA1 – 8CH AI HART Analog Input Module
  2. KJ3002X1-BE1 – 8CH Non-isolated Analog Input
  3. KJ3002X1-BF1 – 8CH Analog Output Module
  4. KJ3001X1-BG1 – 24VDC Discrete Output Module
  5. KJ3001X1-BB1 – 24VDC Isolated Digital Input
  6. KJ3003X1-BA1 – 16CH Digital Input Card
  7. KJ3222X1-BA1 – Redundant 8CH HART AI Series 2
  8. KJ3221X1-BA1 – 8CH 4–20mA Analog Output HART
  9. KJ2003X1-BB1 – DeltaV MD Plus Controller
  10. KJ1501X1-BC1 – DeltaV System Dual Power Supply

 

Category: SKU: Emerson KJ3002X1-BC1 Brand:

Description

Emerson KJ3002X1-BC1 DeltaV M‑Series 8‑Channel Analog Input Module (VE4003S1B2 / 12P0681X072)

 

Product Introduction

The KJ3002X1-BC1 is an isolated analog input I/O card for the Emerson DeltaV distributed control system, belonging to the DeltaV M‑Series I/O family, with alternate part numbers VE4003S1B2 and 12P0681X072. It acquires standard 4–20 mA process signals from field transmitters and converts them into digital values for the DeltaV controller. Featuring channel‑to‑channel isolation, 16‑bit high‑resolution sampling and built‑in diagnostic circuits, it effectively suppresses common‑mode noise and protects the backplane from field‑side surges.

This module supports hot‑swap operation, allowing replacement without shutting down the entire control node, which minimizes plant downtime during maintenance. It can be deployed in both simplex and redundant I/O architectures, suitable for continuous process monitoring. Front‑panel LED indicators provide clear status feedback for power, communication, channel faults and module health. It carries hazardous area approvals including Class I, Division 2 and ATEX Ex ec IIC Gc for installation in classified industrial zones.

KJ3002X1-BC1

Specification Parameters

Item Specification
Brand Emerson
Model KJ3002X1-BC1
Alternate PN VE4003S1B2, 12P0681X072
Platform DeltaV DCS, M‑Series I/O
Channel Count 8 isolated analog input channels
Input Signal 4–20 mA
Resolution 16‑bit
Isolation Channel‑to‑channel isolation
Operation Mode Hot swappable
Diagnostic Per‑channel fault detection, LED status indication
Operating Temperature -40 °C ~ +70 °C
Certification CE, Class I Div 2, ATEX Ex ec IIC Gc
Mounting DeltaV M‑Series I/O carrier base
Power Supply Powered from DeltaV I/O carrier

 

Application Scenarios

  • Oil & gas upstream, refinery and pipeline process control
  • Power plant boiler, turbine and auxiliary monitoring systems
  • Chemical, petrochemical and pharmaceutical batch & continuous processes
  • Water & wastewater treatment plants
  • Pulp and paper manufacturing lines
  • Mining and mineral processing control cabinets
  • Food & beverage process automation
  • Legacy DeltaV system retrofit and spare replacement projects

 

Recommended 10 Related Models

  1. KJ3002X1-BA1 – 8CH AI HART Analog Input Module
  2. KJ3002X1-BE1 – 8CH Non-isolated Analog Input
  3. KJ3002X1-BF1 – 8CH Analog Output Module
  4. KJ3001X1-BG1 – 24VDC Discrete Output Module
  5. KJ3001X1-BB1 – 24VDC Isolated Digital Input
  6. KJ3003X1-BA1 – 16CH Digital Input Card
  7. KJ3222X1-BA1 – Redundant 8CH HART AI Series 2
  8. KJ3221X1-BA1 – 8CH 4–20mA Analog Output HART
  9. KJ2003X1-BB1 – DeltaV MD Plus Controller
  10. KJ1501X1-BC1 – DeltaV System Dual Power Supply

 

FAQ

Q1: What signal type does KJ3002X1-BC1 accept? A1: It is designed for 4–20 mA analog signals from two‑wire or four‑wire process transmitters. It does not support thermocouple or RTD inputs directly.

Q2: Can this module be hot swapped? A2: Yes. It supports hot swap on compatible M‑Series carriers. Follow DeltaV maintenance procedures to avoid transient alarm bursts during insertion/removal.

Q3: Is KJ3002X1-BC1 still in active production? A3: It is a mature legacy M‑Series I/O product. Most available stock is new surplus or fully tested refurbished spares for system maintenance and replacement.

Q4: Does it support HART communication? A4: This BC1 variant is standard 4–20mA analog input without native HART. Select KJ3002X1-BA1 if HART multi‑drop function is required.

Q5: Can I use it in hazardous areas? A5: Yes. It is certified for Class I Division 2 and ATEX Ex ec IIC Gc. Installation must follow local hazardous area wiring and barrier rules.

Q6: What carrier base do I need for installation? A6: It must be fitted onto a matching DeltaV M‑Series I/O carrier base, which provides backplane communication and module power.