Description
ELAU PacDrive MG3-1G-1G-PM SERCOS Gateway / Communication Module, Industrial Automation Spare Part
Product Core Overview
The MG3-1G-1G-PM is an ELAU (Schneider Electric) PacDrive MG3 series high-speed SERCOS communication gateway module. It acts as a bus converter and signal repeater within legacy PacDrive M servo systems, bridging between the motion controller and distributed servo drives or iSH axis networks. The suffix 1G-1G-PM defines dual fibre-optic SERCOS ports with PM fibre configuration.This module supports real-time synchronous motion data transmission for multi-axis applications such as packaging, converting and printing machines. It is factory end-of-life, stocked exclusively as maintenance spare for existing PacDrive installations. Hot replacement can restore SERCOS bus communication rapidly and minimise machine downtime during breakdowns.
Main Technical Specifications

MG3-1G-1G-PM
| Item | Specification |
|---|---|
| Brand | ELAU (Schneider Electric) |
| Model | MG3-1G-1G-PM |
| Series | PacDrive MG3 SERCOS Gateway |
| Product Type | Fibre Optic SERCOS Bus Repeater / Gateway |
| Port Configuration | 2 × SERCOS fibre ports, PM fibre interface |
| Supply Voltage | 24 VDC (±10% tolerance), reverse polarity protection |
| Bus Standard | SERCOS II real-time motion bus |
| Transmission Medium | Plastic-clad PM optical fibre |
| Cycle Time | Compatible with standard PacDrive SERCOS sync cycle |
| Operation Temperature | 0 ℃ ~ +55 ℃ |
| Ambient Humidity | 5%–90% RH, non-condensing |
| Protection Rating | IP20 (cabinet internal mounting) |
| Mounting | DIN rail mounting |
| Diagnostic | Onboard status, link and fault LED indicators |
| Protection | Overvoltage, undervoltage, ESD protection |
| Application | PacDrive C400 / C600 / MAX / iSH servo systems, packaging, slitter, printing machinery |
Quality Control Procedure
- Visual Incoming Inspection: Check housing, fibre transceiver sockets, 24V terminal block, label, serial number and casing integrity.
- ESD Controlled Handling: All inspection and testing performed on grounded anti-static workstation with ESD wrist strap.
- Power-on Burn-in Test: Energise 24VDC continuously for 4 hours; monitor LED status and temperature stability.
- Optical Link Test: Connect paired PM SERCOS fibre cables to verify transmit / receive link signal.
- System Bus Test: Integrate with PacDrive controller and servo drives, validate bus scanning and real-time communication.
- Compatibility Validation: Confirm firmware revision matches the original machine SERCOS topology.
- Data Archiving: Record serial number and full test report, attach inspection sticker, vacuum anti-static packaging.
- Pre-shipment Audit: Double-check full model suffix, fibre type (PM) and quantity before dispatch.
Recommended Related Models & Order Codes (15pcs)
- MG3-1G-1G-GM
- MG3-2G-2G-PM
- C400/A8/1/1/1/00
- C600/A8/0/1/0/00
- MAX-4/11/03/032/99/1/1/00
- iSHPS-5
- DB-5
- MC-4/11/05/400
- MC-2/11/05/400
- SH100/40060/0/1/00
- SH30701P02A2000
- SM-070/10/0/0/00
- SM-100/10/0/0/00
- SCL055
- SCL100
Frequently Asked Questions
Q1: Can MG3-1G-1G-PM replace MG3-1G-1G-GM directly?A: Same MG3 hardware platform; difference is fibre type (PM vs GM). Fibre cables must match the transceiver type. Mismatched fibre will cause SERCOS link failure.
Q2: Is this module discontinued?A: Yes, ELAU PacDrive MG3 series is end-of-life. Available stock is original surplus or fully tested refurbished spare parts.
Q3: Can I hot swap the MG3 gateway while the machine is running?A: Hot swap is not recommended. Perform LOTO procedure and cut off 24VDC supply before removal, otherwise SERCOS bus will drop and trigger axis faults.
Q4: Link fault LED illuminates after installation, what should I check?A: Verify PM fibre cable cleanliness, fibre direction (TX/RX cross), fibre damage, bus topology termination and SERCOS address configuration in PacDrive project.
Q5: Warranty terms?A: Original surplus new: 12-month warranty. Refurbished tested stock: 6-month warranty. Damage caused by wrong fibre type, miswiring, ESD or overvoltage is excluded.
Q6: Commissioning software?A: ELAU PacDrive Software (PDS). The existing SERCOS ring topology must be backed up before replacement.
Installation & Configuration Guide
Pre-installation Preparation
- Confirm cabinet environment: clean, low dust, no condensation, separate from high-power inverters.
- Prepare ESD protection, insulated screwdriver, matched PM SERCOS fibre cables and PacDrive project backup.
- Back up the full SERCOS bus topology and axis parameters before removing the faulty gateway.
Installation Steps
- Execute LOTO lockout-tagout, cut off 24VDC control power of the MG3 module.
- Carefully unplug optical fibre connectors (do not touch the fibre end face), then disconnect 24V wiring. Release DIN rail latch and remove unit.
- Unpack new spare under ESD protection; keep fibre ports capped when unused to avoid contamination.
- Mount MG3-1G-1G-PM firmly on DIN rail and lock the latch.
- Wire 24VDC power supply, connect PM fibre cables strictly following TX-to-RX cross connection rules.
- Secure fibre routing, avoid sharp bending and excessive tension on optical fibres.
- Check terminal tightening and protective earth connection.
Configuration & Commissioning
- Restore 24VDC supply and observe front panel link LEDs.
- Open PacDrive Software and connect to the PacDrive motion controller.
- Scan the SERCOS ring, confirm all gateways, drives and axes are detected online.
- Verify bus topology, node address and communication cycle parameters match the saved project.
- Run manual jog test for each servo axis, check encoder feedback and motion response.
- Test electronic cam, flying shear and synchronisation functions under manual mode.
- Clear all residual alarms after system self-diagnosis passes.
- Switch machine back to automatic production mode and save commissioning log.
Maintenance Notes
- Fibre end faces are extremely sensitive to dust and fingerprints; clean only with dedicated fibre cleaning tools.
- Do not bend PM fibre below the minimum bend radius specified by ELAU.
- Keep ventilation slots free of dust; overheating will cause intermittent SERCOS dropout.
- Store spare modules in dry anti-static packaging with fibre port dust caps installed.