Consilium (Salwico) NSAC-1 Addressable Fire Alarm Control Module

 

Product Details

The Consilium NSAC-1 (Salwico NSAC-1) is a classic analogue addressable fire alarm control core board, originally developed for marine and offshore fire safety systems. It operates on 24V DC power supply and works with Salwico/Consilium fire detector loops. This legacy safety module polls addressable smoke, heat and flame detectors on the signal loop, processes fire and fault signals, displays zone information and triggers alarm relay outputs. It is widely used as spare replacement for old marine fire detection cabinets and complies with marine classification society requirements.

NSAC-1

Applications

  • Cargo ships, container vessels, tankers and passenger ships
  • Offshore oil & gas platforms and floating production units
  • Onshore petrochemical fire & gas safety systems
  • Power plant fire protection control cabinets
  • Harbour terminal safety monitoring rooms
  • Large industrial warehouse fire detection systems
  • FPSO and marine rig safety retrofit projects
  • Legacy Salwico fire alarm system maintenance & spare backup

 

Related Series Models (8 pcs)

  1. NSAC-2
  2. NSAC-3
  3. NSDP-1
  4. NSIO-1
  5. NSSU-1
  6. NSDU-1
  7. NSBU-1
  8. NSRI-1

 

Key Features

  • Analogue addressable loop design for marine fire safety
  • 24V DC operating voltage, low power consumption
  • Strong vibration and EMC resistance for shipboard environment
  • Distinguishes real fire alarm, pre-alarm and fault signals
  • Built-in non-volatile event log storage
  • Relay outputs for horn, beacon and fire suppression linkage
  • Zone status LED indicators for quick status check
  • Approved for marine applications by major classification societies

 

Main Functions

  • Continuous polling of all addressable fire detectors on the loop
  • Analogue signal evaluation to reduce false alarms
  • Pre-alarm and fire alarm confirmation judgment
  • Latch alarm status and activate audible & visual alarm devices
  • Report open circuit, short circuit and detector fault conditions
  • Store alarm time, zone and detector address history records
  • Provide dry contact relay signals for interlock with ventilation / fire dampers
  • Communicate status data to remote mimic panel or ship alarm monitoring system