Allen‑Bradley 2094-BC02-M02-S, Kinetix 6000 Integrated Axis Module, 200/230V, 2kW Converter + Axis Drive

Model Order Number Description
4kW Integrated Converter Axis 2094-BC04-M03-S 4kW BC integrated axis with STO
Axis-only Module 2kW 2094-BM02-S Kinetix 6000 axis module, STO
Axis-only Module 3kW 2094-BM03-S 3kW BM servo axis
Line Filter 2094-FILTER EMC input filter for Kinetix 6000
External Brake Resistor 2094-R02 Regen resistor pack
SERCOS Fiber Cable 2090-SCxxx SERCOS fiber optic jumper
MP 2kW Servo Motor MPL-B4530K-MJ72AA Matching 2kW MP motor
Motor Power Cable 2090-CPWM7DF-16AA MP motor power cable
Encoder Feedback Cable 2090-CFBM7DF-CEAA Hi-res encoder cable
230V 7kW Bus Converter 2094-BC07 Bus converter only, no axis
Kinetix 5700 Replacement Drive 2198-H040-ERS EtherNet/IP newer servo drive
STO Terminal Breakout 2094-TBSTO STO safety terminal accessory
Cooling Fan Kit 2094-FAN-BC Replacement fan for BC modules
Logix SERCOS Interface Card 1756-M08SE 8-axis SERCOS interface module
Motion Analyzer Software MOTION-ANALYZER Rockwell servo sizing & tuning tool
Category: SKU: Allen 2094-BC02-M02-S, Brand:

Description

Allen‑Bradley 2094-BC02-M02-S, Kinetix 6000 Integrated Axis Module, 200/230V, 2kW Converter + Axis Drive

 

Core Product Introduction

The 2094-BC02-M02-S is an integrated converter and axis module for the Rockwell Kinetix 6000 multi-axis servo drive platform. It combines a shared DC-bus power converter section and one servo axis control stage in a single unit. It supports position, velocity and torque control over SERCOS interface, designed for matched Allen‑Bradley MP-series servo motors. Typical applications include packaging machinery, material handling, metal cutting, printing and automated assembly lines. This module features safe torque-off (STO) safety function. It is mature legacy hardware, mostly supplied as spare replacement for existing Kinetix 6000 installations.

2094-BC02-M02-S

Main Technical Specifications

 

Item Parameter
Catalog No. 2094-BC02-M02-S
Series Kinetix 6000
Function Integrated Bus Converter + Single Axis Module
Input Voltage 200–230 VAC, 3-phase, 50/60 Hz
Continuous Power Rating 2 kW
DC Bus Shared DC bus for Kinetix 6000 axis modules
Communication SERCOS fiber interface
Safety Safe Torque Off (STO) SIL2 / PLd
Feedback Incremental encoder / HiRes encoder
Control Modes Position, velocity, torque
Protection Overcurrent, overvoltage, undervoltage, overtemperature, short circuit, encoder fault
Enclosure Rating IP20
Operating Temperature 0 °C ~ +45 °C
Storage Temperature -40 °C ~ +85 °C
Humidity 5%–95% RH, non-condensing
Mounting Panel backplate vertical mounting
Weight ~4.3 kg
Certifications cULus, CE
Lifecycle Status EOL, spare stock only

 

Quality Control Procedure

  1. Visual & Label Inspection: Verify original Rockwell label, catalog number 2094-BC02-M02-S, serial number, power terminals, SERCOS fiber ports, motor/encoder connectors; no burn marks, bent pins or corrosion.
  2. Control Power Boot Test: Apply 24 VDC control supply, confirm power LED, self-test sequence, no abnormal standby current or overheating.
  3. AC Input Pre-charge & DC Bus Test: Apply 200–230V three-phase mains, check pre-charge circuit and stable DC bus voltage build-up.
  4. SERCOS Communication Test: Connect SERCOS master, verify fiber link, drive identification and parameter upload/download.
  5. Encoder Feedback Channel Test: Connect MP-series motor encoder, confirm position reading and zero offset.
  6. Output Power Stage Test: Low-current jog test, check three-phase output balance and current regulation.
  7. STO Safety Circuit Test: Trigger STO circuit, verify torque removal and corresponding fault code.
  8. Fault Alarm Simulation: Simulate overtemp, overvoltage and enable loss to confirm safe shutdown and alarm reporting.
  9. Firmware Compatibility Check: Confirm firmware version matches machine SERCOS master and motor database.
  10. Packaging & Traceability: Anti-static bag + foam cushioning, serial-number linked QC report before shipment.

 

Frequently Asked Questions (FAQ)

Q1: What does BC stand for?A1: BC = Bus Converter. This unit supplies DC bus power for itself and additional Kinetix 6000 axis modules (2094-BMxx).

Q2: What is the difference between 2094-BC02-M02-S and 2094-BC02-M02?A2: The suffix -S means STO (Safe Torque Off) safety function. The non-S version has no built-in STO safety circuit. They are not drop-in interchangeable if the machine safety circuit relies on STO.

Q3: Can I mix 2094-BMxx axis modules with this BC converter?A3: Yes. 2094-BCxx provides the DC bus supply; 2094-BMxx are axis-only modules without converter, they tap the shared DC bus.

Q4: What software is used for commissioning?A4: RSLogix 5000 / Studio5000, plus Motion Analyzer for servo sizing and tuning. SERCOS motion control is configured in the Logix controller.

Q5: Can it drive third-party servo motors?A5: Not recommended. Tuning parameters, encoder protocols and motor characteristic tables are optimized for Allen‑Bradley MP-series motors.

Q6: What is the replacement platform for Kinetix 6000?A6: Kinetix 5500 / Kinetix 5700 are the successors. They use EtherNet/IP instead of SERCOS; wiring, bus and program migration are required, not plug-and-play.

 

Installation & Configuration Guide

  1. Pre-install Preparation: 200–230V 3-phase supply, 24VDC control power, SERCOS fiber cable, MP-series servo motor, encoder cable, STO safety wiring, Studio5000.
  2. Cabinet Layout: Vertical mounting, maintain specified top/bottom airflow clearance, separate power and feedback wiring.
  3. Wiring: AC mains input, DC bus interconnections, 24V control, motor power, encoder, STO safety circuit, enable and stop signals.
  4. SERCOS Ring Setup: Install fiber cables following Tx/Rx direction, complete SERCOS ring termination.
  5. Power-up sequence: 24V control first, then three-phase AC mains; check no major faults.
  6. Firmware and motor configuration: Load matching firmware, select correct MP motor catalog number, run motor identification.
  7. SERCOS axis mapping: Assign axis address, link to Logix motion tags, configure velocity/position/torque limits.
  8. STO safety validation: Test STO circuit to confirm reliable torque removal.
  9. Commissioning: Jog in velocity mode first, then homing and position moves; tune gains, test limits and emergency stop.
  10. Backup: Save controller project, drive parameter set and firmware revision to machine archive.

Warning: High DC bus voltage remains after mains disconnection; respect discharge time before touching terminals. Reversing SERCOS fiber Tx/Rx will cause communication failure.

 

Related Kinetix 6000 Models & Accessories (15 pcs)

 

Model Order Number Description
4kW Integrated Converter Axis 2094-BC04-M03-S 4kW BC integrated axis with STO
Axis-only Module 2kW 2094-BM02-S Kinetix 6000 axis module, STO
Axis-only Module 3kW 2094-BM03-S 3kW BM servo axis
Line Filter 2094-FILTER EMC input filter for Kinetix 6000
External Brake Resistor 2094-R02 Regen resistor pack
SERCOS Fiber Cable 2090-SCxxx SERCOS fiber optic jumper
MP 2kW Servo Motor MPL-B4530K-MJ72AA Matching 2kW MP motor
Motor Power Cable 2090-CPWM7DF-16AA MP motor power cable
Encoder Feedback Cable 2090-CFBM7DF-CEAA Hi-res encoder cable
230V 7kW Bus Converter 2094-BC07 Bus converter only, no axis
Kinetix 5700 Replacement Drive 2198-H040-ERS EtherNet/IP newer servo drive
STO Terminal Breakout 2094-TBSTO STO safety terminal accessory
Cooling Fan Kit 2094-FAN-BC Replacement fan for BC modules
Logix SERCOS Interface Card 1756-M08SE 8-axis SERCOS interface module
Motion Analyzer Software MOTION-ANALYZER Rockwell servo sizing & tuning tool