Description
Product Title
Allen‑Bradley 1756‑PAR2, ControlLogix 85–265 VAC Redundant Power Supply Assembly Bundle
Core Product Introduction
The 1756‑PAR2 is a complete factory packaged redundant AC power supply kit for Rockwell Automation 1756 ControlLogix chassis. It consists of two AC power supply modules, a redundant combiner module and dedicated interconnection cables, delivering seamless bumpless power redundancy for critical automation racks. This assembly accepts wide-range AC mains input and supplies stable multi-rail DC power to the ControlLogix backplane. If one power supply unit fails or its AC source is lost, the second supply takes over automatically without interrupting controller, I/O or communication modules. It is widely deployed in power generation, oil & gas, water treatment and process plants where continuous uptime is mandatory. The 1756‑PAR2 is active production and commonly specified for new redundant rack builds and spare replacement of legacy redundant power assemblies.

1756-PAR2
Main Technical Specifications
| Item | Parameter |
|---|---|
| Catalog Number | 1756-PAR2 |
| Platform | 1756 ControlLogix Chassis |
| Input Voltage | 85 ~ 265 VAC, 47–63 Hz |
| Backplane Output | 5 VDC @ 13 A; 3.3 VDC @ 4 A; 1.2 VDC @ 1.5 A; 24 VDC @ 2.8 A |
| Rated Output Power | 75 W |
| Redundancy Mode | Active/active redundant, automatic failover |
| Kit Contents | 2 × AC power supplies, 1 × combiner module, CPR2 redundant cables |
| Operating Temperature | 0 °C ~ +60 °C |
| Storage Temperature | -40 °C ~ +85 °C |
| Humidity | 5%–95% RH, non-condensing |
| Shock / Vibration | IEC 60068 compliant for industrial rack mounting |
| Mounting | Installs into standard 1756 ControlLogix chassis slots |
| Status Indicators | OK, Fault, Input Power LED on each supply and combiner |
| Certifications | cULus, CE, CCC |
| Lifecycle Status | Active |
| Country of Origin | Mexico |
| Warranty | 1 Year standard Rockwell warranty |
Quality Control Procedure
- Visual & Label Inspection: Verify original Allen‑Bradley branding, 1756‑PAR2 part marking, serial numbers, housing integrity, connector pins and cable insulation, no burn marks or corrosion.
- Individual Power Supply Bench Test: Apply 120 VAC and 240 VAC input to each PSU separately; confirm power rail voltages, OK LED, no overheating or ripple out of tolerance.
- Redundancy Combiner Function Test: Install both supplies to combiner with CPR2 cables, confirm combiner status indicators.
- Failover Simulation Test: Cycle AC input to one supply while the other remains powered; validate bumpless switchover, no backplane voltage drop and no controller fault.
- Overload Protection Test: Apply controlled overload to confirm current limiting and fault indication without permanent damage.
- Isolation & Hi-pot Test: Verify input-to-backplane isolation meets factory safety specifications.
- LED Diagnostic Check: Trigger loss of input voltage and simulate internal fault to confirm fault LED reporting.
- Cable Interconnection Check: Inspect CPR2 redundant cables for continuity and proper locking latching.
- Firmware / Hardware Revision Validation: Confirm compatible hardware revision for target ControlLogix chassis series.
- Packaging & Traceability: Anti-static packaging, foam protection, serial-number linked QC record before shipment.
Frequently Asked Questions (FAQ)
Q1: What is the difference between 1756-PAR2 and 1756-PBR2?A1: 1756- is AC input redundant bundle (85–265 VAC). 1756-PBR2 is 24 VDC input redundant power supply bundle for DC source applications. They are not interchangeable.
Q2: Does 1756- occupy two slots in the ControlLogix rack?A2: Yes. The two power supply units each take one chassis slot, plus the combiner module is mounted with the assembly. You must reserve two power slots in your 1756 rack layout.
Q3: Can I mix a 1756- supply with a standalone PA75 supply?A3: Not supported. Redundant operation requires matched pair within the bundle and the dedicated combiner plus CPR2 cables.
Q4: Is hot-swap supported for one PSU while the rack remains online?A4: Yes, in redundant configuration, one power supply may be replaced live while the second unit maintains backplane power, following Rockwell hot-swap safety procedures.
Q5: What is 1756-PAR2K?A5: 1756-PAR2K is the conformal-coated variant for corrosive, high-humidity or harsh industrial environments.
Q6: Does it work with ControlLogix XT racks?A6: Standard 1756- is for standard temperature racks. For XT (-25 °C to +70 °C) racks select 1756-PAXTR redundant power series.
Installation & Configuration Guide
- Pre-install Preparation: Confirm 1756 chassis type, two independent isolated AC power feeds, CPR2 interconnection cables, ESD wristband and Rockwell 1756 power installation manual.
- Chassis Power-down: Isolate all rack power before inserting modules.
- Module Insertion: Insert both power supplies and combiner assembly into dedicated power slots; lock module latches securely.
- Redundant Cabling: Connect CPR2 cables between the two PSU units and combiner module, ensure connectors fully clicked.
- AC Source Wiring: Feed each supply from separate upstream AC circuits for true source redundancy. Use appropriate fusing on each AC input.
- Protective Earth: Connect protective ground terminal of each supply to cabinet safety earth.
- Power-up First Source: Energize one AC feed, verify OK LED, stable backplane voltage and no fault alarms.
- Energize Second Feed: Switch on the second AC supply, confirm both units enter active redundant state.
- Redundancy Commissioning Test: Perform live source loss test: cut AC to one supply and verify rack remains powered with no controller reset. Restore AC and confirm auto-rejoin.
- System Documentation: Record serial numbers, test results and upstream breaker layout in site electrical package.
Warning: Always isolate AC mains before disassembly. Do not rely solely on redundancy for maintenance lockout/tagout.
Related Rockwell ControlLogix Power & Accessory Models & Order Number Recommendation (15 pcs)
| Model | Order Number | Description |
|---|---|---|
| Redundant DC Power Bundle | 1756-PBR2 | 24VDC redundant power supply assembly |
| Conformal Coated AC Redundant Bundle | 1756-PAR2K | harsh environment coated version |
| Standard AC Power Supply | 1756-PA75 | Single 85–265VAC ControlLogix power supply |
| Standard DC Power Supply | 1756-PB75 | Single 24VDC ControlLogix power supply |
| Redundant AC XT Power | 1756-PAXTR | XT wide temp redundant AC PSU |
| Redundant DC XT Power | 1756-PBXTR | XT wide temp redundant DC PSU |
| Redundant Cable Set | 1756- | Redundant power interconnection cable |
| PA72 AC Power Supply | 1756-PA72 | 85–265VAC lower wattage AC PSU |
| PB72 DC Power Supply | 1756-PB72 | 24VDC lower wattage DC PSU |
| PA75R Redundant PSU | 1756-PA75R | Individual redundant AC power module |
| PB75R Redundant PSU | 1756-PB75R | Individual redundant DC power module |
| 17-slot ControlLogix Chassis | 1756-A17 | 17 slot standard ControlLogix rack |
| 13-slot ControlLogix Chassis | 1756-A13 | 13 slot standard ControlLogix rack |
| 10-slot ControlLogix Chassis | 1756-A10 | 10 slot standard ControlLogix rack |
| Power Supply Fan Assembly | 1756-FAN1 | Replacement cooling fan for ControlLogix PSU |