Description
ABB PM665 3BDS005799R1 PowerPC Processor Module for Advant Controller 160 (AC160) DCS System
Model & Part Number
- Type: PM665
- Order Code: 3BDS005799R1
- Manufacturer: ABB
- Product Category: Central Processor Unit / Controller Module
- Compatible System: Advant Controller 160 (AC160), Advant Master DCS

PM665 3BDS005799R1
Product Description
The PM665 (3BDS005799R1) is a high-performance PowerPC-based processor module designed for ABB Advant Controller 160 distributed control platform. It integrates an on-board redundancy voter, high-speed link interface and dedicated speed input channel, built to execute real-time process control, sequence logic, event timestamping and rotating machinery speed measurement. It supports multi-processor coordination, hot standby redundancy and seamless integration with Advant Fieldbus 100, Profibus DP and Modbus protocols. Widely deployed in legacy Advant Master DCS, this unit remains a critical spare part for plant maintenance, system retrofitting and life extension projects in heavy process industries.
Technical Specifications
| Item | Specification |
|---|---|
| CPU Core | 32-bit PowerPC processor |
| Onboard Function | Redundancy voter, high-speed link, speed input |
| Power Supply | 24 VDC (19.2 ~ 28.8 VDC) |
| Communication Ports | High-speed internal link, serial ports, fieldbus interface |
| Supported Protocols | Advant Fieldbus 100, Profibus DP, Modbus RTU/TCP, RCOM+ |
| Max I/O Capacity | Approx. 1500 I/O tags per controller |
| Multi-Processor Support | Up to 6 PM665 modules in one AC160 node |
| Operating Temperature | 0°C ~ +55°C |
| Storage Temperature | -40°C ~ +70°C |
| Relative Humidity | 5% ~ 95%, non-condensing |
| Enclosure Rating | IP20 (for cabinet mounting only) |
| Dimension | 252 mm × 273 mm × 40 mm |
| Net Weight | 2.04 kg |
| Compliance | EU RoHS directive 2011/65/EU |
| Redundancy Mode | Dual processor hot standby, bumpless switchover |
Application Fields
- Thermal power & combined cycle power plants
- Oil, gas and petrochemical refining
- Steel, metallurgy and continuous casting lines
- Water & wastewater treatment facilities
- Pulp and paper process control
- Cement and mining process automation
- Rotary machinery monitoring & turbine control
- Legacy DCS life extension and migration projects
Brand Profile (ABB)
ABB is a global technology leader in electrification, automation, motion and digitalization. Formed from the merger of ASEA (Sweden) and BBC (Switzerland) in 1988, ABB has developed a complete DCS, PLC, motor drive and protection relay portfolio. The Advant Master control series, including AC110, AC160, AC450, was one of ABB’s flagship process control lines launched for heavy industry in the 1990s. While newer System 800xA has become the mainstream platform, ABB continues spare part and service support for Advant Master installed base, helping asset owners extend the service life of existing plants without full system replacement.
Related News & Industry Events
The PM665 belongs to the mature Advant Controller 160 series, a legacy DCS controller. In recent years, the main industry trend is plant owners sourcing original or tested spare modules to avoid emergency shutdowns, as many Advant Master systems have reached their original design lifecycle. Multiple refineries and power utilities run phased migration plans from AC160 toward ABB System 800xA, while keeping PM665 stock for interim maintenance. Supply chain tightening for discontinued DCS spare modules has pushed reliable tested units into high demand for global after-market automation suppliers.
Usage Scenarios
- Primary control node of Advant AC160 DCS for continuous process regulation
- Redundant CPU pair for safety-critical boiler, turbine and compressor control
- High-speed pulse / speed acquisition for turbines, fans and rotating equipment
- Sequence of events (SOE) logging with high-precision time stamping
- Interfacing S600 local I/O and S800 remote I/O stations
- Gateway connection between legacy Advant bus and third-party Modbus / Profibus devices
- Retrofit replacement for failed original during plant turnaround
- Coordination with HMI, alarm management and historian servers
Functional Advantages
- Built-in redundancy voter enables bumpless hot standby switchover, minimizing unplanned downtime
- Native high-speed input channel dedicated for rotating equipment speed measurement
- Multi-processor parallel operation for splitting large control workloads
- Rich native fieldbus support to connect legacy I/O and field instruments
- Precise source-level timestamping for alarm and sequence-of-event audit
- Rugged industrial design resistant to vibration and electromagnetic interference in control cabinets
- Modular hot-swap capable (within redundant configuration)
- Fully compatible with original Advant Master engineering toolset
- Long-proven field reliability with decades of operating records in process industries
Recommended Related Products (16 pcs)
- ABB PM664 Processor Module
- ABB PM668 Processor Module
- ABB 3BSE005890R1 S800 I/O Module
- ABB 3BSE013230R1 DI801 Digital Input
- ABB 3BSE013231R1 DO801 Digital Output
- ABB 3BSE008516R1 AI810 Analog Input
- ABB 3BSE008520R1 AO810 Analog Output
- ABB 3BDS005798R1 PM663
- ABB 3BSE020508R1 TU810 Terminal Unit
- ABB AC800M PM861 Controller
- ABB PM866 Controller
- ABB 3BSE040662R1 CI854 Profibus Interface
- ABB 3BSE041434R1 CI853 Fieldbus Interface
- ABB 3BSE018103R1 SD832 Power Supply
- ABB 3BSE018105R1 SD833 Power Supply
- ABB 3BDS005800R1 Backplane Unit
Installation Instruction
- Confirm cabinet power is fully disconnected before module insertion.
- Verify the backplane slot is for Advant controller rack, check pin condition for damage or oxidation.
- Align the board edge connector with the backplane, insert smoothly and lock the front fastening screws evenly.
- Wire the 24 VDC control power to the dedicated power terminal, observe polarity strictly.
- Connect high-speed link cable, fieldbus cable and speed input wiring according to the original loop drawing; use shielded twisted pair for fieldbus.
- Configure redundancy pairing if dual hot standby is required, set node address via engineering software.
- Power on the rack gradually, check front LED indicators for status, communication and fault signals.
- Download the Advant Master control application, verify I/O mapping, SOE timestamp and speed input channel.
- Perform redundancy switchover test manually to confirm bumpless transfer without process trip.
- Close cabinet door properly to maintain IP20 protection and reduce EMI interference.
Maintenance Guide
- Daily: Inspect module status LEDs, check for overheating, loose terminals or abnormal cabinet fan noise.
- Periodic: Clean dust on module surface and ventilation slots; do not use liquid cleaner directly on PCB.
- Routine test: Execute redundancy health check, bus communication status and speed input calibration every shutdown window.
- Troubleshooting: If fault LED lights up, check power supply stability first, then bus termination, cable shield grounding and partner redundant module status.
- Spare part management: Store standby in anti-static packaging, controlled temperature and humidity environment.
- Repair rule: Do not disassemble the module casing or modify internal components; return to certified automation service vendor for testing and repair.
- Lifecycle note: This is legacy hardware. Prepare migration planning toward System 800xA alongside spare stock management.