ABB 5SHY3545L0009 HiPak Asymmetric IGCT Module, Order Code: 3BHB013085R0001 for ACS6000 Medium Voltage Drives

  1. ABB 5SHY3545L0005 IGCT Module
  2. ABB 5SHY3545L0010 IGCT Module
  3. ABB 5SHX2645L0004 Reverse Conducting IGCT
  4. ABB 3BHB003154R0101 Gate Unit
  5. ABB 3BHB006454R0001 Snubber Capacitor
  6. ABB ACS6000 Control Unit
  7. ABB 3BHB004623R0001 Voltage Measurement Board
  8. ABB Water Cooling Heat Sink
  9. ABB Fiber Optic Gate Cable
  10. ABB 3BHB009885R0001 Phase Module Assembly
  11. ABB 5SHY35L4520 IGCT
  12. ABB 3BHB013088R0001 (5SHY3545L0010)
  13. ABB Inverter Pressure Clamp Kit
  14. ABB Gate Power Supply
  15. ABB ACS6000 Drive Monitoring Software
  16. ABB Phase Module Test Bench
Category: SKU: ABB 5SHY3545L0009 Brand:

Description

ABB 5SHY3545L0009 HiPak Asymmetric IGCT Module, Order Code: 3BHB013085R0001 for ACS6000 Medium Voltage Drives

 

Model & Part Number

  • Type: 5SHY3545L0009
  • Order No.: 3BHB013085R0001
  • Manufacturer: ABB, Country of Origin: Switzerland
  • Category: Press-pack Integrated Gate-Commutated Thyristor (IGCT) power module
  • Series: HiPak 5SHY family
  • Compatible System: ABB ACS6000 medium voltage inverter, high-power STATCOM, SVC and grid converters

5SHY3545L0009 3BHB013085R0001

Product Description

The 5SHY3545L0009 (3BHB013085R0001) is an asymmetric HiPak IGCT press-pack power semiconductor with integrated gate unit and freewheeling diode. It adopts fiber-optic gate triggering to achieve high-speed, low-loss hard switching for medium-voltage power conversion. The press-pack construction supports double-sided cooling, offering superior thermal cycling tolerance and high reliability for continuous heavy-duty operation. This unit is a core spare for ABB ACS6000 MV drive platforms, widely stocked by mining, metal, oil & gas and power plant asset owners for drive maintenance and system life extensionABB Group.

 

Technical Specifications

Item Specification
Device Type Asymmetric IGCT, integrated freewheeling diode
Repetitive Peak Off-state Voltage (VDRM) 4500 V
RMS On-state Current (IT GQM) 4500 A
Non-repetitive Surge Current (10 ms) 55 kA
On-state Voltage ≤1.5 V @ 4500 A, 25°C
Gate Interface Fiber optic trigger, galvanic isolation
Junction Operating Temperature -40°C ~ +125°C
Thermal Resistance (case to heat sink) 0.01 K/W
Cooling Method Double-sided water cooling
Weight 3.74 kg
Compliance CE
Customs Code 85413000

 

Application Fields

  • ABB ACS6000 medium voltage variable frequency drives
  • Mining SAG mills, ball mills and large conveyor drives
  • Metallurgy rolling mill main drives
  • Oil & gas large compressor and pump MV drives
  • Static Var Compensator (SVC) and STATCOM grid stabilizers
  • Renewable energy high-power grid-tied converters
  • Rail traction and marine high-power converters
  • Legacy ACS6000 drive overhaul and spare replacement

 

Brand Profile (ABB HiPak IGCT)

ABB invented and industrialized IGCT technology, and the HiPak series has become the mainstream power semiconductor for medium-voltage high-power converters. Compared with GTO thyristors, IGCT eliminates the bulky snubber circuit, reduces system volume and improves switching performance. The 5SHY3545L0009 is a classic high-current model in the HiPak lineup, serving as the standard power core for the globally deployed ACS6000 drive series. ABB continues to support the installed base, and this part remains a critical high-value spare.

 

Related News & Industry Events

5SHY3545L0009 is a mature high-power IGCT spare for . Original factory lead times are long, and unexpected failure can halt large-capacity production equipment. End users maintain tested spare modules in inventory for mill and compressor trains. Tested and fully inspected surplus IGCTs are widely traded in the aftermarket, with strict electrical and pressure testing required before shipment.

 

Usage Scenarios

  1. Main power switching device for medium voltage inverter phase units
  2. High-current switching for SVC / STATCOM reactive power compensation systems
  3. Direct drop-in replacement for failed 5SHY3545L0009 in existing phase modules
  4. Phase unit reconstruction and expansion of cabinets
  5. High-power four-quadrant drive for rolling mills and mining mills
  6. Grid side converter for wind farm and solar central inverter systems
  7. Troubleshooting short-circuit, overcurrent and phase leg fault issues
  8. Spare inventory for critical 24/7 process and mining assets

 

Functional Advantages

  • 4500 V / 4500 A high rating, suitable for large power medium voltage conversion
  • Press-pack double-sided cooling design, excellent thermal performance
  • Integrated freewheeling diode, simplifies phase unit layout
  • Fiber optic gate drive, complete high-voltage isolation and strong EMI immunity
  • Low stray inductance, low switching loss and high switching reliability
  • High surge current withstand capability for short-circuit tolerance
  • Mature matching with gate unit and snubber circuit
  • Long service life and high thermal cycling resistance for heavy industrial cycles
  • Standard footprint for direct replacement in original phase module

 

Recommended Related Products (16 pcs)

  1. ABB 5SHY3545L0005 IGCT Module
  2. ABB 5SHY3545L0010 IGCT Module
  3. ABB 5SHX2645L0004 Reverse Conducting IGCT
  4. ABB 3BHB003154R0101 Gate Unit
  5. ABB 3BHB006454R0001 Snubber Capacitor
  6. ABB Control Unit
  7. ABB 3BHB004623R0001 Voltage Measurement Board
  8. ABB Water Cooling Heat Sink
  9. ABB Fiber Optic Gate Cable
  10. ABB 3BHB009885R0001 Phase Module Assembly
  11. ABB 5SHY35L4520 IGCT
  12. ABB 3BHB013088R0001 (5SHY3545L0010)
  13. ABB Inverter Pressure Clamp Kit
  14. ABB Gate Power Supply
  15. ABB Drive Monitoring Software
  16. ABB Phase Module Test Bench

 

Installation Instruction

  1. Lock out / tag out medium voltage and DC bus power; confirm zero energy.
  2. Discharge DC bus capacitors completely before disassembling the phase unit.
  3. Remove the old IGCT, clean heat sink contact surfaces carefully.
  4. Apply proper thermal interface material evenly on both cooling surfaces.
  5. Place new 5SHY3545L0009, align the press-pack stack, apply specified clamping force strictly.
  6. Connect fiber optic gate cables, avoid sharp bending and excessive tension.
  7. Reassemble snubber, diode and busbar connections; check torque values.
  8. Restore cooling water circuit, test for water leakage.
  9. Perform low-voltage gate trigger test to verify fiber communication and gate function.
  10. Run insulation resistance and hi-pot test before applying medium voltage.
  11. Energize drive, run idle test and check gate diagnostic status.
  12. Perform no-load and loaded ramp test, confirm no overcurrent or gate faults.

 

Maintenance Guide

  • Daily Check: Monitor phase module temperature, cooling water flow and drive fault log.
  • Periodic Maintenance: Inspect clamping pressure, cooling circuit, fiber cable aging and connector cleanliness.
  • Routine Test: Perform insulation test and gate function check during drive turnaround.
  • Troubleshooting: Gate communication loss → fiber damage, gate board failure; Overcurrent / short circuit → IGCT punch-through, busbar insulation failure.
  • Spare Handling: Store spare IGCT in dry, low-vibration environment; protect contact surfaces and fiber receptacles.
  • Repair Notice: Press-pack IGCT is non-repairable on-site. Return failed unit to qualified ABB power electronics vendor for failure analysis.
  • Lifecycle Note: 5SHY3545L0009 is a core legacy HiPak device. Maintain spare inventory for ; evaluate new generation power stacks for future full drive replacement.