3BSE050092R65, ABB PFEA113-65 High-end Tension Electronics, IP65 enclosed version for web tension measurement

Model Order Number Description
DIN rail PFEA113 PFEA113-20 / 3BSE050092R60 IP20 DIN mount version
Mid-range tension unit PFEA112 2 load cells, Profibus
Basic tension unit PFEA111 2 load cells, no Profibus
Pressductor load cell PFTL101A PillowBlock tension load cell
Radial load cell PFTL201C Radial type load cell
Load cell cable 3BSE004166R1 Shielded Pressductor extension cable
Profibus DP connector 3BSE003275R1 DP bus terminator plug
PFEA113 front keypad cover 3BSE050112R1 Spare protective window
Tension display accessory PFEA-DISPLAY Remote display
Profibus DP repeater PBDP-REP Bus signal repeater
PFEA122 PFEA122 High temp variant
Calibration weight kit ABB-CAL-WEIGHT Tension calibration mass set
IP65 gland kit 3BSE050114R1 Spare cable gland set
PFEA11 series manual PFEA11-MANUAL Operation & service manual
Profibus gateway PDP800 Symphony Plus DP master module
Category: SKU: 3BSE050092R65, PFEA113-65 Brand:

Description

3BSE050092R65, ABB PFEA113-65 High-end Tension Electronics, IP65 enclosed version for web tension measurement

 

Core Product Introduction

PFEA113-65 (3BSE050092R65) is the top model of ABB PFEA11 series tension amplifier, designed for Pressductor load cells in web processing lines. It supports up to 4 load cells, provides high-precision tension acquisition, signal conditioning, filtering and transmission to PLC/DCS via Profibus-DP. It features local LCD display, remote zero, gain scheduling, multi-segment roll combination (max 3 units cascaded for 12 load cells). Widely used in paper, film, foil, textile, coating, slitting, printing and battery electrode production lines. This suffix -65 variant is IP65 enclosed cabinet type, suitable for dusty, splashing workshop floor installation, different from DIN-rail IP20 PFEA113-20.

PFEA113-65 3BSE050092R65

Main Technical Specifications

Item Parameter
Part Number PFEA113-65 / 3BSE050092R65
Manufacturer ABB Measurement & Analytics, Origin: Sweden
Function Web tension measurement & signal transmitter
Enclosure Rating IP65
Power Supply 100–240 VAC 47–63Hz or 24VDC (18–36VDC)
Power Consumption Max 15W
Load Cell Support Up to 4 pcs Pressductor load cells, excitation: 0.5A rms @330Hz
Inputs 1 digital input (remote zero / gain switch), 2 analog cascade inputs
Outputs 6 configurable analog outputs (0–21mA / voltage), 4 digital alarm outputs
Communication Profibus-DP
Display 2×16 multi-language LCD, units: N, kN, kg, lbs, N/m, pli etc.
Filter Setting Adjustable step response: 5/15/30/75/250/750/1500ms
Cascade Up to 3 PFEA113 chained for segmented winder applications
Operating Temperature 0°C ~ +50°C
Storage Temperature -40°C ~ +85°C
Humidity 5%–95% RH, non-condensing
Certifications CE, UL61010, CSA
Lifecycle Status Mature, spare stock available
Weight ~5.95 kg

 

Quality Control Procedure

  1. Visual & Label Inspection: Verify ABB original marking, part number 3BSE050092R65 / PFEA113-65, serial number, enclosure seal integrity, cable glands and LCD screen without scratches.
  2. Power Boot Test: Apply AC or DC supply, confirm power LED, LCD startup and self-check, no abnormal heat.
  3. Load Cell Excitation Test: Check 330Hz 0.5A excitation output for 4 load cell channels.
  4. Tension Signal Calibration Test: Inject standard strain signal, verify reading accuracy, zero and span adjustment.
  5. Analog Output Test: Check each AO channel linearity under varied tension value.
  6. Digital Input / Remote Zero Test: Trigger DI to execute remote zero and gain switching.
  7. Profibus-DP Communication Test: Connect to Profibus master, read tension value, alarm status and diagnostic data.
  8. Cascade Function Test: Link with another , verify multi-unit synchronized measurement.
  9. Alarm & Diagnostic Simulation: Simulate load cell break, cable short, over-range to check DO alarm output and fault code.
  10. Packaging & Traceability: Shock-proof packing, serial-number QC report before shipment.

 

Frequently Asked Questions (FAQ)

Q1: What is the difference between -20 and -65?A1: -20 = IP20 DIN rail mount for control cabinet; -65 = IP65 sealed enclosure, direct machine / floor mounting for harsh production environment. Internal function and firmware are identical.

Q2: What load cells match ?A2: ABB Pressductor PillowBlock and Radial load cells (PFTL series). Not compatible with generic strain gauge load cells without Pressductor excitation.

Q3: Can it run as a closed-loop tension controller?A3: is a measurement electronics / signal transmitter only. It outputs tension signal to PLC or drive controller; it does NOT contain PID closed-loop control algorithm itself.

Q4: What software is used for parameter setup?A4: Local keypad + LCD for most setup; Profibus can also write parameters online. No separate PC configuration software required.

Q5: Can multiple be connected together?A5: Yes, up to 3 units cascaded for wide-width segmented winder, total 12 load cells.

Q6: What communication does it support?A6: Profibus-DP only. If Ethernet is required, select other ABB tension system or external Profibus gateway.

 

Installation & Configuration Guide

  1. Pre-install Preparation: PFTL Pressductor load cells, shielded sensor cable, Profibus DP cable, AC/DC power source.
  2. Mounting: Fix IP65 enclosure on machine frame, keep away from strong vibration and heat source.
  3. Wiring: Power, load cell cables, analog outputs, Profibus-DP bus; use shielded cable and single-point earthing.
  4. Power Up: Switch on power, pass self-diagnosis, confirm no load cell fault alarm.
  5. Load Cell Assignment: Set channel quantity, sensor type, rated load via front keypad.
  6. Zero & Span Calibration: Perform mechanical zero and span calibration with known weight.
  7. Output Configuration: Set each AO as tension, deviation or alarm signal, choose filter time constant.
  8. Profibus Setup: Set station address, baud rate, map tension and diagnostic data to PLC.
  9. Cascade setup (if needed): Enable inter-unit analog link for multi-segment roll.
  10. Backup: Record all calibration parameters, save fault code list and machine recipe.

Warning: Pressductor load cell cables must be kept away from inverter power cables to avoid excitation signal interference; wrong wiring will cause unstable tension reading or hardware damage.

 

Related ABB Tension Series Models & Accessories (15 pcs)

Model Order Number Description
DIN rail -20 / 3BSE050092R60 IP20 DIN mount version
Mid-range tension unit PFEA112 2 load cells, Profibus
Basic tension unit PFEA111 2 load cells, no Profibus
Pressductor load cell PFTL101A PillowBlock tension load cell
Radial load cell PFTL201C Radial type load cell
Load cell cable 3BSE004166R1 Shielded Pressductor extension cable
Profibus DP connector 3BSE003275R1 DP bus terminator plug
front keypad cover 3BSE050112R1 Spare protective window
Tension display accessory PFEA-DISPLAY Remote display
Profibus DP repeater PBDP-REP Bus signal repeater
PFEA122 PFEA122 High temp variant
Calibration weight kit ABB-CAL-WEIGHT Tension calibration mass set
IP65 gland kit 3BSE050114R1 Spare cable gland set
PFEA11 series manual PFEA11-MANUAL Operation & service manual
Profibus gateway PDP800 Symphony Plus DP master module