The 3500/22M (PN:288055-01) is the Transient Data Interface (TDI) module for the Bently Nevada 3500 machinery protection system (Baker Hughes). It integrates the functions of the older 3500/20 Rack Interface Module (RIM) and transient data acquisition processor. Installed in slot 1 right next to the rack power supply, it serves as the main communication hub for the entire 3500 rack, collecting steady-state values and high-resolution transient waveform data from all M-series monitor modules and uploading data to System 1 diagnostic software. It also handles rack configuration, status supervision and alarm relay output. Critically, the TDI is outside the protection trip path; its failure will not affect the hardware protection trip logic of the 3500 system.

288055-01
Key Features & Benefits
- Central data gateway for the whole 3500 rack, compatible with 3500 M-series monitor modules (3500/40M, 3500/42M etc.)
- Captures both steady-state process values and high-speed transient waveform data; supports threshold, event and time-triggered recording
- 16 MB onboard transient memory for pre/post-event waveform storage
- Dual network options: 10/100Base-TX RJ45 Ethernet and 100Base-FX fiber interface
- Front USB‑B port for local configuration, firmware download and troubleshooting; key-lock switch prevents unauthorized configuration modification
- Built-in OK status relay for rack health annunciation
- Front-panel LED indicators: OK, TX/RX, CONFIG OK, Trip Multiply
- SIL 2 certified, API 670 compliant for turbine and rotating machinery protection
- Conformal coated PCB, designed for turbine hall and industrial cabinet environments
- Supports configuration via 3500 configuration software and diagnostic visualization in System 1
Technical Specifications
| Item | Description |
|---|---|
| Manufacturer | Bently Nevada (Baker Hughes) |
| Model | 3500/22M |
| OEM PN | 288055-01 |
| Type | Transient Data Interface (TDI) / Rack Interface Module |
| Mounting Slot | Slot 1 (adjacent to power supply) in 3500 rack |
| Communication | 10/100Base‑TX Ethernet, 100Base‑FX fiber, front USB-B |
| Transient Memory | 16 MB |
| Power Consumption | 10.5 W |
| OK Relay Rating | 5A @ 24VDC / 120VAC |
| Operating Temperature | -10°C ~ +65°C |
| Software | 3500 Configuration Software, System 1 |
| Certification | SIL2, API 670 |
| OEM Status | Discontinued, supplied as surplus / refurbished spare |
| Application | Steam/gas turbine, compressor, pump, generator supervisory instrumentation (TSI) |
Typical Applications
3500/22M is mandatory for each standard 3500 rack in power plants, refineries and petrochemical facilities. It transmits vibration, shaft displacement, speed and temperature data from Bently Nevada monitor cards to System 1 for advanced vibration spectrum analysis, fault trending and root-cause diagnosis. It is a high-priority spare for turbine TSI rack maintenance and planned outages of rotating machinery protection systems.
Matching Companion Modules
- 3500/05 System Rack and power supplies
- 3500/40M Proximitor monitor, 3500/42M Velocity monitor, 3500/45M Speed module
- Proximity probes, velocity transducers, extension cables
- System 1 machinery condition monitoring platform
Operation Notes
This module must be placed in slot 1 next to the power supply and cannot be installed in ordinary monitor slots. Verify firmware compatibility with all other M-series monitor cards before replacement. After swap, download rack configuration and test Ethernet communication, relay alarm output and waveform capture function. It does not participate in the hardware trip loop, so machinery protection remains active even if the TDI loses communication.
FAQ
Q: Can the 3500/22M replace the old 3500/20 RIM directly? A: It functionally replaces the 3500/20 plus TDXnet, but rack configuration and software licensing must be validated; it is not always drop-in without configuration adjustment.
Q: Can it send data to DeltaV or Honeywell Experion DCS? A: It communicates primarily with System 1. To connect to DCS, additional Modbus gateway or OPC server is required. It is not a native DCS module.
Q: Will a faulty 3500/22M cause the turbine protection to trip? A: No. The protection trip path is independent of the TDI; loss of TDI only loses data communication and waveform recording, not hardware protection.