Bently Nevada 3500/15 106M1079-01 Power Converter Module, Back-End DC Conversion Unit for 3500 Machinery Protection Rack AC Power Supply Assembly, Requires Matching AC PIM Module 106M1081-01
Technical Specifications
- Catalog Number: 106M1079-01
- Brand: Bently Nevada (Baker Hughes)
- Product Type: Half-height rack-mounted DC power converter module for 3500/15 universal AC power group
- Matching mating module: 106M1081-01 (Universal AC Power Input Module, PIM)
- Input to this converter: Regulated internal feed from 106M1081-01
- Output: Multiple regulated DC rails to the 3500 rack backplane to power all monitor, relay and communication modules
- Compatible Input Range (with paired 106M1081-01): 85 ~ 264 VAC, 47–63 Hz worldwide universal mains
- Hot Swap: Supported only in dual redundant power configuration
- Status Indicator: Front panel “SUPPLY OK” LED
- Protection: Surge, overvoltage, overcurrent, short-circuit, overtemperature protection
- Mounting: Rear half-height dedicated power slot at the far left of standard 3500 chassis
- Operating Temperature: -20 °C ~ +60 °C (-4 °F ~ +140 °F)
- Humidity: 5%–95% RH, non‑condensing
- Compliance: API 670, CE, industrial EMC, Class I Div 2 approval
- Lifecycle Status: Mature active spare part, widely used for 3500 legacy TSI racks
- Country of Origin: USA
- Weight: ~0.9 kg
Key Features & Advantages
- Backend conversion unit of the universal AC 3500/15 power set: It cannot work standalone; must pair with 106M1081-01 AC PIM front module.
- Wide universal mains compatibility: When paired with 106M1081-01, supports both 110 VAC and 220 VAC plant power without jumper reconfiguration.
- Redundant parallel operation: Two complete 3500/15 assemblies can run in parallel to provide uninterrupted power for safety-critical machinery protection.
- Hot-swap capability: Online replacement allowed when the second redundant power assembly remains healthy.
- Low-noise regulated DC output: Clean backplane power reduces noise interference to proximity probes, accelerometer and position monitor channels.
- System health reporting: Supply OK status is visible locally and available in 3500 configuration software and System 1 for remote alarming.
- Direct drop-in replacement: Compatible with existing 3500 racks designed for the new universal AC 3500/15 power series.
- Distinct generation boundary: Not interchangeable with older legacy 127610-01 converter modules (different internal circuit, incompatible with old PIMs).
Application Fields
- Gas / steam turbine and centrifugal compressor machinery protection cabinets
- Refinery, pipeline and offshore rotating equipment TSI monitoring systems
- Power plant boiler feed pump, generator and large fan vibration protection racks
- Petrochemical expander and LNG compression machinery monitoring
- Steel mill, pulp and paper critical rotating machine condition protection
- Retrofit spare replacement for 3500 racks using universal AC 3500/15 power assemblies
- Safety-critical machinery protection systems compliant with API 670
Related Product Recommendations
- 106M1081-01: Matching universal AC PIM (power input module)
- 127610-01: Obsolete older generation AC converter module
- 133292-01 +133300-01: 3500/15 DC power supply assembly
- 3500/42M: Vibration and position monitor module
- 3500/45: Accelerometer monitor module
- 3500/53: Relay output module
- 3500/92: Ethernet communication gateway module
- 3500 rack chassis and backplane
- System 1 machinery condition monitoring software
- AC input surge protection terminal block
Installation & Maintenance
Installation
- Power down the rack before inserting unless performing approved redundant hot-swap.
- Install 106M1079-01 in the rear half-height power slot; the front adjacent slot must be fitted with 106M1081-01.
- Separate AC input cabling away from proximity probe coaxial cables and low-level sensor wiring to avoid EMI.
- Confirm AC input voltage is within 85–264 VAC before energizing the matched assembly.
- For redundant setup, use two independent AC power sources for the two 3500/15 power groups.
- After power on, check the “SUPPLY OK” LED and confirm power health status in the 3500 software.
- Do not cross-match this converter with old 125840 series PIM modules; they are electrically incompatible.
- Keep cabinet ventilation unobstructed to prevent thermal shutdown.
Maintenance
- Inspect LED status, terminal tightness and dust accumulation during unit turnaround.
- Alarm trending in System 1 can reveal early power degradation; intermittent supply alarms often relate to loose wiring or ageing components.
- Periodically test redundant switchover by isolating one AC feed while the other power assembly stays online.
- For spare stocking, keep the matched pair (106M1079-01 +106M1081-01) together; they are calibrated and sold as one functional assembly.
- If hot-swap is performed, strictly follow site LOTO and safety permit procedures.
- After replacement, verify all monitor channels, relay trip chains and communication links are stable.
- No field repairable internal components; do not open the module housing.
- Record serial numbers, power configuration and redundant test results in TSI asset files.