Bently Nevada 3500/60-01-00 163179-01 + 133819-01 6-Channel Temperature Monitor Product Introduction
Product Overview
The Bently Nevada 3500/60-01-00 assembly, consisting of the 163179-01 front panel main temperature monitoring module and the matching 133819-01 non-isolated RTD/TC backplane I/O module, is a dedicated 6-channel universal temperature monitor designed exclusively for the 3500 Machinery Protection System. As a specialized thermal monitoring node in the 3500 series, it natively supports mixed input of Resistance Temperature Detectors (RTD) and Thermocouples (TC), delivering high-precision continuous temperature measurement and independent protection alarm logic for critical rotating machinery components .
This module pair is fully compliant with API 670 and ISO 10816 industrial machinery protection standards. It integrates signal conditioning, 24-bit high-resolution AD conversion, real-time temperature calculation, and backplane data transmission functions. It can independently complete full thermal protection for 6 temperature measurement points, and seamlessly transmit all temperature data and alarm status to the 3500/22M TDI or 3500/25 communication gateway through the rack backplane. It is the standard dedicated monitoring module for bearing metal temperature, casing surface temperature, lube oil temperature, and other thermal parameter protection scenarios for critical rotating equipment .
Core Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Bently Nevada (Baker Hughes) |
| Part Number Combination | 3500/60-01-00 (163179-01 Front Panel + 133819-01 Non-Isolated Backplane I/O Module) |
| Number of Independent Channels | 6 fully configurable channels |
| Supported Sensor Types | PT100, PT1000 RTDs; Type J/K/T/E/R/S/B Thermocouples |
| Measurement Accuracy | ±0.5°C (RTD), ±1°C (Thermocouple) |
| Input Impedance | > 10 MΩ per channel |
| Power Consumption | 9 W, powered via 3500 rack backplane |
| Operating Temperature Range | -30°C to +65°C (-22°F to +150°F) |
| Storage Temperature Range | -40°C to +85°C (-40°F to +185°F) |
| Relative Humidity | 5% to 95% non-condensing |
| Alarm Configuration | 2 independent programmable setpoints (Alert / Danger) per channel, with adjustable delay |
| Analog Output | 4-20 mA buffered output per channel, corresponding to full-scale temperature range |
| Form Factor | Standard 3500 series half-height module |
| Hot Swap Support | Fully supported for online replacement without interrupting other channels |
| Redundancy Support | Compatible with Triple Modular Redundant (TMR) system configurations |
| Certifications | CE, UL, CSA, ATEX, IECEx, Class 1 Division 2 / Zone 2 hazardous area certified |
Key Features
- Universal Mixed Sensor Compatibility: A single module supports both RTD and Thermocouple inputs, allowing users to freely mix different sensor types across the 6 channels according to on-site requirements. This eliminates the need to deploy separate RTD monitors and TC monitors, drastically reducing spare part inventory types and system integration complexity .
- High-Precision Stable Measurement: The 24-bit high-resolution ADC and dedicated cold-junction compensation circuit ensure long-term stable and accurate temperature reading even in harsh industrial environments with severe EMI interference. It automatically compensates for cable resistance errors, eliminating the need for manual field calibration for most standard applications .
- Full Self-Diagnostic Protection: Built-in continuous sensor health monitoring function automatically detects probe open circuit, short circuit, cable disconnection and other faults, and triggers “Sensor Not OK” alarm immediately. The front-panel LED indicators (OK, Bypass, Channel Alarm) provide intuitive visual feedback of operating status for on-site technicians .
- Flexible Alarm & Integration Capability: Each channel independently supports two-level Alert and Danger alarm setpoints, with freely adjustable alarm delay time. The 4-20 mA analog output can be directly connected to the plant DCS or SIS system, while the backplane bus seamlessly transmits all temperature data to Bently Nevada System 1 diagnostic platform for historical trending and thermal fault analysis .
- Rugged Industrial Design: The non-isolated 133819-01 backplane module features internal integrated signal terminations, eliminating the need for extra external terminal blocks and reducing on-site wiring workload. The module’s wide operating temperature range and anti-vibration design ensure reliable long-term operation in heavy industrial facilities .
Installation & Compatibility Notes
- The 163179-01 front panel and 133819-01 backplane I/O module are strictly matched components for the non-isolated version of 3500/60 temperature monitor. They cannot be intermixed with isolated TC I/O modules or other 3500 series monitoring module backplanes, as mismatched hardware will cause signal channel failure or backplane communication conflict .
- This half-height module can be installed in any general-purpose slot of the 3500 rack, no fixed slot restriction. When performing hot-swap replacement, confirm that the “Bypass” state of the corresponding channels is activated in the 3500 configuration software in advance, to avoid false alarms caused by signal interruption during the replacement process .
- All field sensor signal cables must use shielded dedicated temperature signal cables, and the shielding layer must be single-point grounded at the rack side. Signal cables must be routed separately from high-voltage power cables to avoid EMI interference that causes measurement data drift or distortion .
- This 3500/60-01-00 assembly is fully backward-compatible with all 3500/05 racks, 3500/15 universal AC power supplies, 3500/22M TDI and all other M-series modules, making it the ideal upgrade replacement for legacy 3500/60 temperature monitors in existing 3500 system deployments .
Typical Applications
This universal temperature monitor is widely deployed on critical rotating assets including large steam turbines, centrifugal compressors, gas turbines, generators, industrial pumps and fans across power generation, oil & gas, petrochemical, metallurgy and heavy industrial facilities. It provides continuous, reliable thermal protection for bearing bushes, machine casings, lube oil systems and other key components, helping operators detect early thermal faults such as bearing overheating, lubrication failure and abnormal casing temperature rise, effectively preventing unplanned downtime and catastrophic equipment thermal damage .